Evidence map›Paper›PMID 21981807›Full record

ArticleMedical engineering & physics2012

Reproducibility of IVUS border detection for carotid atherosclerotic plaque assessment.

Gail M Siewiorek, Natasha A Loghmanpour, Brion M Winston, Mark H Wholey, Ender A Finol

Abstract read
In one paragraph

Article in Medical engineering & physics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Utilization of Intravascular Ultrasound during Carotid Artery Stenting.The International journal of angiology : official publication of the International College of Angiology, Inc · 2015
    Article
  3. Progress in atherosclerotic plaque imaging.World journal of radiology · 2012
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gail M SiewiorekBiomedical Engineering Department, Carnegie Mellon University, Pittsburgh, PA, United States.
Natasha A Loghmanpour
Brion M Winston
Mark H Wholey
Ender A Finol

Funding

Training in Biomechanics in Regenerative MedicineT32EB003392 · NIBIB · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI WOO, SAVIO L-Y. · 2005 to 2020
$4.0M
NIBIB NIH HHS T32 EB003391-01NIBIB NIH HHS T32 EB003392
6 · The paper itself

Abstract

Plaque composition is a potentially important diagnostic feature for carotid artery stenting (CAS). The purpose of this investigation is to evaluate the reproducibility of manual border correction in intravascular ultrasound with virtual histology (VH IVUS) images. Three images each were obtained from 51 CAS datasets on which automatic border detection was corrected manually by two trained observers. Plaque was classified using the definitions from the CAPITAL (Carotid Artery Plaque Virtual Histology Evaluation) study, listed in order from least to most pathological: no plaque, pathological intimal thickening, fibroatheroma, fibrocalcific, calcified fibroatheroma, thin-cap fibroatheroma, and calcified thin-cap fibroatheroma. Inter-observer variability was quantified using both weighted and unweighted Kappa statistics. Bland-Altman analysis was used to compare the cross-sectional areas of the vessel and lumen. Agreement using necrotic core percentage as the criterion was evaluated using the unweighted Kappa statistic. Agreement between classifications of plaque type was evaluated using the weighted Kappa statistic. There was substantial agreement between the observers based on necrotic core percentage (κ=0.63), while the agreement was moderate (κ(quadratic)=0.60) based on plaque classification. Due to the time-consuming nature of manual border detection, an improved automatic border detection algorithm is necessary for using VH IVUS as a diagnostic tool for assessing the suitability of patients with carotid artery occlusive disease for CAS.

Indexed as

AgedAged, 80 and overCarotid ArteriesCarotid Artery DiseasesFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedObserver VariationPlaque, AtheroscleroticReproducibility of ResultsUltrasonography

Identifiers

PMID21981807
PMCPMC3262102

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.