Evidence map›Paper›PMID 22350685›Full record

Trial reportJournal of thrombosis and thrombolysis2012

Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo.

Carlos L Alviar, Armando Tellez, Michael Wang, Pamela Potts, Doug Smith, Manus Tsui, Wladyslaw Budzynski, Albert E Raizner, Neal S Kleiman, Eli I Lev and 2 more

Abstract readClinical Trial
PubMed Publisher
In one paragraph

Trial report in Journal of thrombosis and thrombolysis, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 3 countries.

Carlos L AlviarSkirball Center for Cardiovascular Research, Cardiovascular Research Foundation, 8 Corporate Drive, Orangeburg, NY 10962, USA.
Armando Tellez
Michael Wang
Pamela Potts
Doug Smith
Manus Tsui
Wladyslaw Budzynski
Albert E Raizner
Neal S Kleiman
Eli I Lev
Juan F Granada
Greg L Kaluza
Cardiovascular Research Foundation · USHouston Methodist · USRoyal College of Physicians · GBUniversity of Houston · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We previously found paclitaxel-eluting polymer-coated stents causing more human platelet-monocyte complex formation than bare metal stents in vitro. Presently, we examined patterns of platelet activation and adhesion after exposure to 6 nanofilm HAp-coated (HAp-nano) stents, 6 HAp-microporous-coated (HAp-micro) stents, 5 HAp sirolimus-eluting microporous-coated (HAp-SES) stents and 5 cobalt-chromium stents (BMS) deployed in an in vitro flow system. Blood obtained from healthy volunteers was circulated and sampled at 0, 10, 30 and 60 min. By flow cytometry, there were no significant differences in P-Selectin expression between the 4 stent types (HAp-nano = 32.5%; HAp-micro = 42.5%, HAp-SES = 10.23%, BMS = 7% change from baseline at 60 min, p = NS); PAC-1 antibody binding (HAp-nano = 11.8%; HAp-micro = 2.9%, HAp-SES = 18%, BMS = 6.4% change from baseline at 60 min, p = NS) or PMC formation (HAp-nano = 21.6%; HAp-micro = 4%, HAp-SES = 6.6%, BMS = 17.4% change from baseline at 60 min, p = NS). The 4 stent types did not differ in the average number of platelet clusters >10 μm in diameter by SEM (HAp-nano = 2.39 ± 5.75; HAp-micro = 2.26 ± 3.43; HAp-SES = 1.93 ± 3.24; BMS = 1.94 ± 2.41, p = NS). The majority of the struts in each stent group were only mildly covered by platelets, (HAp-nano = 80%, HAp-micro = 61%, HAp-SES = 78% and BMS = 52.1%, p = NS). The HAp-microporous-coated stents (ECD) attracted slightly more proteinaceous material than bare metal stents (HAp-micro = 35% struts with complete protein coverage, P < 0.0001 vs. other 3 stent types). In conclusion, biomimetic stent coating with nanofilm or microporous hydroxyapatite, even when eluting low-dose sirolimus, does not increase the platelet activation in circulating human blood, or platelet adhesion to stent surface when compared to bare metal stents in vitro.

Indexed as

Coated Materials, BiocompatibleDrug-Eluting StentsDurapatiteMaterials TestingAdultFemaleHumansImmunosuppressive AgentsMalePlatelet ActivationSirolimusTime FactorsCoated Materials, BiocompatibleDurapatiteImmunosuppressive AgentsSirolimus

Identifiers

PMID22350685
OpenAlexW2069872541

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.