Evidence map›Paper›PMID 22977321›Full record

ArticleKorean journal of radiology

Artificial luminal narrowing on contrast-enhanced magnetic resonance angiograms on an occasion of stent-assisted coiling of intracranial aneurysm: in vitro comparison using two different stents with variable imaging parameters.

Jee Hyun Seok, Hyun Seok Choi, So-Lyung Jung, Kook-Jin Ahn, Myeong Jin Kim, Yong Sam Shin, Bum-soo Kim

Open access · hybridAbstract readComparative Study
In one paragraph

Article in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.2field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Usefulness of contrast-enhanced and TOF MR angiography for follow-up after low-profile stent-assisted coil embolization of intracranial aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2018
    Article
  4. Effects of Imaging Parameters on the Quality of Contrast-Enhanced MR Angiography of Cerebral Aneurysms Treated Using Stent-Assisted Coiling: A Phantom Study.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2017
    Article
  5. Article
  6. Will Fluoroscopic Follow-up after Stent-Assisted Coiling of Cerebral Aneurysms Provide Information on Recanalization?Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2014
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jee Hyun SeokDepartment of Radiology, Seoul St. Mary's Hospital, The Catholic University of Korea College of Medicine, Seoul 137-701, Korea.
Hyun Seok Choi
So-Lyung Jung
Kook-Jin Ahn
Myeong Jin Kim
Yong Sam Shin
Bum-soo Kim
Catholic University of Korea · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIntracranial stenting for stent-assisted coiling of aneurysms requires adequate follow-up imaging. The aim of this in vitro study was to compare in-stent artificial luminal narrowing on contrast-enhanced MR angiograms (CE-MRA) when applying Neuroform® and Enterprise® stents for stent-assisted coiling. MATERIALS AND

methodsTwo intracranial nitinol stents (Enterprise® and Neuroform®) were placed in silicon tubes and then imaged at 3 T and 1.5 T by the use of a T1-weighted three-dimensional spoiled gradient-echo sequence with minimal TR and TE. CE-MRAs were obtained by using different imaging planes, voxel sizes, and bandwidths, and with or without parallel imaging. Artificial lumen narrowing (ALN) was calculated and the results were compared.

resultsLower magnetic field strength, axial plane perpendicular to axis of stent, and wider bandwidth resulted in a lower ALN on CE-MRA for both stents. Larger voxel size resulted in lower ALN for Neuroform® stent. The parallel imaging acceleration factor did not affect ALN. The mean ALN was lower for Neuroform®, but it was not significant by a paired t test.

conclusionCE-MRA of the stented lumen of vascular phantom was partially impaired with ALN. Consequently, image plane orientation, magnetic field strength, bandwidth, and voxel size should be adjusted appropriately to reduce ALN.

Indexed as

StentsAlloysCerebral AngiographyContrast MediaHumansImaging, Three-DimensionalIntracranial AneurysmIn Vitro TechniquesLinear ModelsMagnetic Resonance AngiographyPhantoms, ImagingReproducibility of ResultsAlloysContrast MedianitinolIntracranial aneurysmIntracranial stentMR angiography

Identifiers

PMID22977321
PMCPMC3435851
OpenAlexW2141192701

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.