Accuracy and limitations of continuous glucose monitoring using spectroscopy in critically ill patients.

Roosmarijn Tm van Hooijdonk, Tineke Winters, Johan C Fischer, Edmée C van Dongen-Lases, James S Krinsley, Jean-Charles Preiser, Marcus J Schultz

Open access · goldAbstract read
In one paragraph

Article in Annals of intensive care, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Glucose Management Technologies for the Critically Ill.Journal of diabetes science and technology · 2019
    Review
  4. Article
  5. Article
  6. Article
  7. Why Have So Many Intravascular Glucose Monitoring Devices Failed?Journal of diabetes science and technology · 2015
    Review
  8. Review
  9. Observational
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Roosmarijn Tm van HooijdonkDepartment of Intensive Care, Academic Medical Center, University of Amsterdam, Room, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands. r.t.vanhooijdonk@amc.uva.nl.
Tineke Winters
Johan C Fischer
Edmée C van Dongen-Lases
James S Krinsley
Jean-Charles Preiser
Marcus J Schultz
Academic Medical Center · NLUniversity of Amsterdam · NLErasmus Hospital · BEStamford Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOptiScanner devices, continuous glucose monitoring devices that perform automated blood draws via a central venous catheter and create plasma through centrifugation, measure plasma glucose levels through mid-infrared spectroscopy at the bedside. The objective of this study was to determine accuracy and practicality of the devices in critically ill patients attempting glycemic control.

methodsThe plasma glucose level was measured by the devices and in comparative plasma samples using Yellow Springs Instrument (YSI) plasma analyzers. After adding several previously unrecognized interferences in the interference library, we reanalyzed the mid-infrared signals and compared the resulting plasma glucose level with the reference value. Results are presented in Clarke error grids, glucose prediction errors and Bland-Altman plots and expressed as correlation coefficients.

resultsWe analyzed 463 comparative samples from 71 patients (median 6 (4 to 9) samples per patient). After calibrating the system, a Clarke error grid showed 100% of the values in zones A or B. The glucose predictor error demonstrated that 86% of the glucose values < 75 mg/dL were within ± 15 mg/dL of the YSI results and 95% ≥ 75 mg/dL were within 20% of the comparative YSI results. Bland-Altman plot showed a bias of -0.6 with limit of agreement of -24.6 to 23.3. The Pearson correlation coefficient was 0.93 and R2 was 0.87. In one third of the patients the devices had to be disconnected prematurely (that is before planned disconnection) because of repeated occlusion alarms suggesting blood draw errors.

conclusionThe devices needed calibration for several previously unrecognized interferences. Thereafter, accuracy of the device to measure plasma glucose levels in 'our cohort' of critically ill patients improved, but external validation is highly recommended. The automated blood draw system of the devices needs further improvement to make this device of value for clinical use (trial registration (Netherlands Trial Register): NTR2864).

Identifiers

PMID24598381
PMCPMC3975731
OpenAlexW2120635165

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.