Evidence mapPaperPMID 24671928Full record

SynthesisThe Cochrane database of systematic reviews2014

Biocompatible dialysis fluids for peritoneal dialysis.

Yeoungjee Cho, David W Johnson, Jonathan C Craig, Giovanni F M Strippoli, Sunil V Badve, Kathryn J Wiggins

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 50 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
50citing papers in PubMed, 3 pooled it
8.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

50 citing papers in PubMed, 3 syntheses or guidelines pooled it, 165 citations in OpenAlex.

  1. Pooled it
  2. Biocompatible dialysis fluids for peritoneal dialysis.The Cochrane database of systematic reviews · 2018
    Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Troxerutin is a novel osmotic agent for peritoneal dialysis with protective cardiovascular actions.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2026
    Article
  9. Review
  10. Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Yeoungjee ChoDepartment of Nephrology, Princess Alexandra Hospital, ARTS Building, Ipswich Rd, Woolloongabba, Queensland, Australia, 4012.
David W Johnson
Jonathan C Craig
Giovanni F M Strippoli
Sunil V Badve
Kathryn J Wiggins
Princess Alexandra Hospital · AUChildren's Hospital at Westmead · AUThe Royal Melbourne Hospital · AUThe University of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe longevity of peritoneal dialysis (PD) is limited by high rates of technique failure, some of which stem from peritoneal membrane injury. 'Biocompatible' PD solutions have been developed to reduce damage to the peritoneal membrane.

objectivesThis review aimed to look at the benefits and harms of biocompatible PD solutions in comparison to standard PD solutions in patients receiving PD. SEARCH

methodsWe searched the Cochrane Renal Group's Specialised Register (28 February 2013), through contact with the Trials Search Co-ordinator using search terms relevant to this review. Studies contained in the Specialised Register are identified through search strategies specifically designed for CENTRAL, MEDLINE and EMBASE, and handsearching conference proceedings. SELECTION CRITERIA: All randomised controlled trials (RCTs) and quasi-RCTs in adults and children comparing the effects of biocompatible PD solutions (neutral pH, lactate-buffered, low glucose degradation product (GDP); neutral pH, bicarbonate (± lactate)-buffered, low GDP; glucose polymer (icodextrin)) in PD were included. Studies of amino acid-based PD solutions were excluded. DATA COLLECTION AND ANALYSIS: Two authors extracted data on study quality and outcomes (including adverse effects). The authors contacted investigators to obtain missing information. Summary estimates of effect were obtained using a random-effects model, and results were expressed as risk ratios (RR) and their 95% confidence intervals (CI) for categorical variables, and mean difference (MD) or standardised mean difference (SMD) and 95% CI for continuous variables. MAIN

resultsThirty-six eligible studies (2719 patients) were identified: Neutral pH, lactate-buffered/bicarbonate (± lactate)-buffered, low GDP PD solution (24); icodextrin (12). Allocation methods and concealment were generally incompletely reported, and adequate in only ten studies (27.8%). Patients lost to follow-up ranged from 0% to 83.4%. Neutral pH, low GDP versus conventional glucose PD solutionBased on generally sub-optimal quality evidence, the use of neutral pH, low GDP PD solutions was associated with larger urine volumes at the end of the studies, up to three years of therapy duration (7 studies, 520 patients: MD 126.39 mL/d, 95% CI 26.73 to 226.05). Improved preservation of residual renal function was evident in studies with greater than 12 month follow-up (6 studies, 360 patients: SMD 0.31, 95% CI 0.10 to 0.52). There was no significant effect on peritonitis, technique failure or adverse events with the use of neutral pH, low GDP PD solutions. Glucose polymer (icodextrin) versus conventional glucose PD solutionThere was a significant reduction in episodes of uncontrolled fluid overload (2 studies, 100 patients: RR 0.30, 95% CI 0.15 to 0.59) and improvement in peritoneal ultrafiltration (4 studies, 102 patients, MD 448.54 mL/d, 95% CI 289.28 to 607.80) without compromising residual renal function (4 studies, 114 patients: SMD 0.12, 95% CI -0.26 to 0.49) or urine output (3 studies, 69 patients: MD -88.88 mL/d, 95% CI -356.88 to 179.12) with icodextrin use. A comparable incidence of adverse events with the icodextrin (four studies) was reported. AUTHORS'

conclusionsBased on generally sub-optimal quality studies, use of neutral pH, low GDP PD solution led to greater urine output and higher residual renal function after use exceeded 12 months. Icodextrin prescription improved peritoneal ultrafiltration and mitigated uncontrolled fluid overload. There were no significant effects on peritonitis, technique survival, patient survival or harms identified with their use. Based on the best available evidence, the use of these 'biocompatible' PD solutions resulted in clinically relevant benefits without added risks of harm.

Indexed as

PeritoneumAdultChildDialysis SolutionsGlucoseHumansHydrogen-Ion ConcentrationKidneyPeritoneal DialysisRandomized Controlled Trials as TopicSolutionsUrineDialysis SolutionsGlucoseSolutions

Identifiers

PMID24671928
OpenAlexW1540312361

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.