Evidence map›Paper›PMID 26745914›Full record

ArticleMedical physics2016

The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections.

Chung Chan, Joyoni Dey, Yariv Grobshtein, Jing Wu, Yi-Hwa Liu, Rachel Lampert, Albert J Sinusas, Chi Liu

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Quantification of intramyocardial blood volume withJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Chung ChanDepartment of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520.
Joyoni DeyDepartment of Physics and Astronomy, Medical Physics Program, Louisiana State University, Baton Rouge, Louisiana 70803.
Yariv GrobshteinGE Healthcare, Haifa 30200, Israel.
Jing WuDepartment of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520.
Yi-Hwa LiuDepartment of Internal Medicine, Yale University, New Haven, Connecticut 06520.
Rachel LampertDepartment of Internal Medicine, Yale University, New Haven, Connecticut 06520.
Albert J SinusasDepartment of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520 and Department of Internal Medicine, Yale University, New Haven, Connecticut 06520.
Chi LiuDepartment of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520.
Yale University · USLouisiana State University · US

Funding

YALE UNIVERSITY CLINICAL AND TRANSLATIONAL SCIENCE AWARD PROGRAMUL1RR024139 · NCRR · YALE UNIVERSITY · PI SHERWIN, ROBERT S · 2006 to 2011
$56.8M
Hybrid Volumetric SPECT/CT Imaging SystemS10RR025555 · NCRR · YALE UNIVERSITY · PI SINUSAS, ALBERT J · 2009 to 2009
$500k
Design and Simulation of a Novel High Performance Cardiac SPECT CameraR21HL102574 · NHLBI · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI DEY, JOYONI · 2011 to 2012
$452k
NCRR NIH HHS 1S10RR025555-01NCRR NIH HHS S10 RR025555NCRR NIH HHS UL1 RR024139NHLBI NIH HHS R21 HL102574NHLBI NIH HHS R21HL102574
6 · The paper itself

Abstract

purposeA dedicated cardiac hybrid single photon emission computed tomography (SPECT)/CT scanner that uses cadmium zinc telluride detectors and multiple pinhole collimators for stationary acquisition offers many advantages. However, the impact of the reconstruction system matrix (SM) dimension on the reconstructed image quality from truncated projections and 19 angular samples acquired on this scanner has not been extensively investigated. In this study, the authors aimed to investigate the impact of the dimensions of SM and the use of body contour derived from adjunctive CT imaging as an object support in reconstruction on this scanner, in relation to background extracardiac activity.

methodsThe authors first simulated a generic SPECT/CT system to image four NCAT phantoms with various levels of extracardiac activity and compared the reconstructions using SM in different dimensions and with/without body contour as a support for quantitative evaluations. The authors then compared the reconstructions of 18 patient studies, which were acquired on a GE Discovery NM570c scanner following injection of different radiotracers, including (99m)Tc-Tetrofosmin and (123)I-mIBG, comparing the scanner's default SM that incompletely covers the body with a large SM that incorporates a patient specific full body contour.

resultsThe simulation studies showed that the reconstructions using a SM that only partially covers the body yielded artifacts on the edge of the field of view (FOV), overestimation of activity and increased nonuniformity in the blood pool for the phantoms with higher relative levels of extracardiac activity. However, the impact on the quantitative accuracy in the high activity region, such as the myocardium, was subtle. On the other hand, an excessively large SM that enclosed the entire body alleviated the artifacts and reduced overestimation in the blood pool, but yielded slight underestimation in myocardium and defect regions. The reconstruction using the larger SM with body contour yielded the most quantitatively accurate results in all the regions of interest for a range of uptake levels in the extracardiac regions. In patient studies, the SM incorporating patient specific body contour minimized extracardiac artifacts, yielded similar myocardial activity, lower blood pool activity, and subsequently improved myocardium-to-blood pool contrast (p < 0.0001) by an average of 7% (range 0%-18%) across all the patients, compared to the reconstructions using the scanner's default SM.

conclusionsTheir results demonstrate that using a large SM that incorporates a CT derived body contour in the reconstruction could improve quantitative accuracy within the FOV for clinical studies with high extracardiac activity.

Indexed as

FemaleHeartHumansImage Processing, Computer-AssistedMaleModels, BiologicalPhantoms, ImagingTomography, Emission-Computed, Single-PhotonTomography, X-Ray Computed

Identifiers

PMID26745914
PMCPMC4691252
OpenAlexW2215605208

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked