ArticleAdvances in therapy2016

Usability and Acceptability of the Abatacept Pre-Filled Autoinjector for the Subcutaneous Treatment of Rheumatoid Arthritis.

Michael Schiff, Joe Koo, Erik Jin, Eric Schiller, Ashley Day, Rebecca Stevens, Christina Laskar

Abstract read
In one paragraph

Article in Advances in therapy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michael SchiffDepartment of Rheumatology, University of Colorado, Denver, CO, USA. michael.schiff@me.com.
Joe KooDevice Operations, Bristol-Myers Squibb, Princeton, NJ, USA.
Erik JinDevice Operations, Bristol-Myers Squibb, Princeton, NJ, USA.
Eric SchillerDevice Operations, Bristol-Myers Squibb, Princeton, NJ, USA.
Ashley DayQualitative Research Specialist, Ipsos-Insight, LLC, Westbury, NY, USA.
Rebecca StevensQualitative Research Specialist, Ipsos-Insight, LLC, Westbury, NY, USA.
Christina LaskarDevice Operations, Bristol-Myers Squibb, Princeton, NJ, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe purpose of the present study was to determine whether the abatacept autoinjector can be used by the intended population without patterns of preventable use errors, and is acceptable when assessed against key user needs.

methodsTwo independently conducted simulated-use studies, with no active drug administered, quantified use errors and evaluated the abatacept autoinjector and competitor devices on key attributes (comfort, control, ease of use, confidence of dose) and overall acceptability. Autoinjector preference was also assessed. Participants were patients with rheumatoid arthritis, caregivers, and healthcare professionals (HCPs). Participants were informed that a new rheumatoid arthritis autoinjector was being tested but were blinded to the intended drug and sponsor identity.

resultsIn the formative (pre-validation) study (n = 54), two high-priority use errors occurred, both of which resulted from protocol non-compliance rather than mental confusion or physical limitations. In the summative (validation) study (n = 99), one high-priority use error occurred; this was deemed a simulated-use study artifact as participant behavior was guided by actual experience associated with the feel of drug delivery into the skin rather than by protocol, so no mitigation steps were considered necessary. Across user groups, average scores were consistently high for the pre-defined key attributes. Overall acceptability scores (7-point scale) were significantly higher for the abatacept versus competitor autoinjectors-formative study: patients 6.7 vs 5.2 (P = 0.0001), caregivers 7.0 vs 4.6 (P = 0.0093), HCPs 6.8 vs 5.1 (P = 0.0020); summative study: patients 6.5 vs 5.9 (P = 0.0404), caregivers 6.8 vs 5.8 (P = 0.0047), HCPs 6.8 vs 5.1 (P = 0.0002). The abatacept autoinjector was preferred to competitor devices: patients 85.7% vs 14.3% (P = 0.00002), caregivers 84.2% vs 15.8% (P = 0.00443), HCPs 95.0% vs 5.0% (P = 0.00004). Positive experiences with the abatacept autoinjector were attributed to the rubberized grip, device size, visualization of dose progression, button ergonomics, and ease of use.

conclusionThe abatacept autoinjector demonstrated usability without patterns of preventable use errors, and with high acceptability ratings across all key attributes assessed. Preference over competitor autoinjectors was due to device ergonomics, visualization of dose progression, confidence of dose delivery, and overall ease of use.

fundingBristol-Myers Squibb.

Indexed as

Patient PreferenceAbataceptAdolescentAdultAgedAntirheumatic AgentsArthritis, RheumatoidDisease ProgressionDrug Delivery SystemsFemaleHumansMaleMiddle AgedNeedlesTreatment OutcomeYoung AdultAbataceptAntirheumatic AgentsAbatacept autoinjectorFailure modes and effects analysisHuman factors engineeringUsabilityValidation testing

Identifiers

PMID26833303
PMCPMC4769728

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.