Trial reportPhysiological reports2016
Exploring the mechanisms underpinning sweating: the development of a specialized ventilated capsule for use with intradermal microdialysis.
Trial report in Physiological reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 50 citations in OpenAlex.
- Exploring the mechanisms underpinning sweating: the development of a specialized ventilated capsule for use with intradermal microdialysis.Physiological reports · 2016Trial
- Inter- and intra-site reliability of forearm sweating induced by pilocarpine iontophoresis.The journal of physiological sciences : JPS · 2026Article
- A micro-to-macroscale and multi-method investigation of human sweating dynamics.Journal of the Royal Society, Interface · 2025Article
- GH and IGF-1 in skin interstitial fluid and blood are associated with heat loss responses in exercising young adults.European journal of applied physiology · 2024Article
- Article
- Separate and combined effects of KAmerican journal of physiology. Regulatory, integrative and comparative physiology · 2019Article
- Local arginase inhibition does not modulate cutaneous vasodilation or sweating in young and older men during exercise.Journal of applied physiology (Bethesda, Md. : 1985) · 2019Article
- Cyclooxygenase-1 and -2 modulate sweating but not cutaneous vasodilation during exercise in the heat in young men.Physiological reports · 2018Article
- The effect of exogenous activation of protease-activated receptor 2 on cutaneous vasodilatation and sweating in young males during rest and exercise in the heat.Temperature (Austin, Tex.) · 2018Article
- Fluid replacement modulates oxidative stress- but not nitric oxide-mediated cutaneous vasodilation and sweating during prolonged exercise in the heat.American journal of physiology. Regulatory, integrative and comparative physiology · 2017Article
- The roles of KAmerican journal of physiology. Regulatory, integrative and comparative physiology · 2017Article
- No effect of ascorbate on cutaneous vasodilation and sweating in older men and those with type 2 diabetes exercising in the heat.Physiological reports · 2017Article
- Nitric oxide synthase and cyclooxygenase modulate β-adrenergic cutaneous vasodilatation and sweating in young men.The Journal of physiology · 2017Article
- The mechanisms underlying the muscle metaboreflex modulation of sweating and cutaneous blood flow in passively heated humans.Physiological reports · 2017Article
- Intradermal administration of atrial natriuretic peptide has no effect on sweating and cutaneous vasodilator responses in young male adults.Temperature (Austin, Tex.) · 2017Article
- Intradermal administration of endothelin-1 attenuates endothelium-dependent and -independent cutaneous vasodilation via Rho kinase in young adults.American journal of physiology. Regulatory, integrative and comparative physiology · 2017Article
- Administration of prostacyclin modulates cutaneous blood flow but not sweating in young and older males: roles for nitric oxide and calcium-activated potassium channels.The Journal of physiology · 2016Article
- The roles of the Na+/K+-ATPase, NKCC, and K+ channels in regulating local sweating and cutaneous blood flow during exercise in humans in vivo.Physiological reports · 2016Article
- K+ channel mechanisms underlying cholinergic cutaneous vasodilation and sweating in young humans: roles of KCa, KATP, and KV channels?American journal of physiology. Regulatory, integrative and comparative physiology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Many studies have aimed to identify the controllers of sweating using ventilated capsules with intradermal microdialysis. It is unclear, however, if the surface area covered by the capsule influences the observed response as a result of differences in the number of sweat glands affected by the infused pharmacological agent relative to the total glands captured by the capsule. We evaluated the area of skin perfused with agents delivered via microdialysis. Thereafter, we developed a specialized sweat capsule (1.1 cm(2)) and compared the sweating response with a classic capsule (2.8 cm(2)). InProtocol 1(n = 6), methacholine was delivered to forearm skin in a dose-dependent manner (1-2000 mmol L(-1)). The area of activated sweat glands was assessed via the modified iodine-paper technique. InProtocol 2(n = 6), the area of inhibited sweat glands induced by ouabain and atropine was assessed during moderate-intensity cycling. Marked variability in the affected skin area was observed (0.9 ± 0.4 to 5.2 ± 1.1 cm(2)). InProtocol 3(n = 6), we compared the attenuation in local sweat rate (LSR) induced by atropine between the new and classic capsule during moderate-intensity cycling. Atropine attenuated sweating as assessed using the new (control: 0.87 ± 0.23 mg min(-1) cm(-2)vs. atropine: 0.54 ± 0.22 mg min(-1) cm(-2);P < 0.01) and classic (control: 0.85 ± 0.33 mg min(-1) cm(-2)vs. atropine: 0.60 ± 0.26 mg min(-1) cm(-2);P = 0.05) capsule designs. Importantly, responses did not differ between capsule designs (P = 0.23). These findings provide critical information regarding the skin surface area perfused by microdialysis and suggest that use of a larger capsule does not alter the mechanistic insight into the sweating response gained when using microdialysis.
Indexed as
Identifiers
What Socratic holds