ArticleDiabetes technology & therapeutics2016
Accuracy of Continuous Glucose Monitoring in Patients After Total Pancreatectomy with Islet Autotransplantation.
Article in Diabetes technology & therapeutics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Optimizing Hybrid Closed-Loop Therapy in Adolescents and Emerging Adults Using the MiniMed 670G System.Diabetes care · 2018Trial
- Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.Langenbeck's archives of surgery · 2025Article
- Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.Intensive care medicine · 2024Article
- Continuous Glucose Monitoring in the Intensive Care Unit Following Total Pancreatectomy with Islet Autotransplantation in Children: Establishing Accuracy of the Dexcom G6 Model.Journal of clinical medicine · 2021Article
- Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.Diabetes technology & therapeutics · 2020Observational
- Total pancreatectomy and islet autotransplantion for chronic and recurrent acute pancreatitis.Current opinion in gastroenterology · 2018Review
- Continuous Glucose Monitor Use and Accuracy in Hospitalized Patients.Diabetes technology & therapeutics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundAmong postsurgical and critically ill patients, malglycemia is associated with increased complications. Continuous glucose monitoring (CGM) in the inpatient population may enhance glycemic control. CGM reliability may be compromised by postsurgical complications such as edema or vascular changes. We utilized Clarke Error Grid (CEG) and Surveillance Error Grid (SEG) analysis to evaluate CGM performance after total pancreatectomy with islet autotransplantation. MATERIALS AND
methodsThis subanalysis evaluated Medtronic Enlite 2 CGM values against YSI serum glucose in seven post-transplant patients (86% female; 38.6 ± 9.4 years) on artificial pancreas for 72 h at transition from intravenous to subcutaneous insulin. Sensor recalibration occurred for absolute relative difference (ARD) ≥20% x2, ≥30% x1, or by investigator discretion based on trend.
resultsSensor analysis showed mean absolute relative difference (MARD) of 11.0% ± 11.5%. The sensors were recalibrated 8.3 times/day; active sensor was switched 1.4 times/day. Calibration factor was 7.692 ± 3.786 mg/nA·dL (target = 1.5-20 mg/nA·dL). CEG analysis showed 86.1% of pairs in Zone A (clinically accurate zone) and 99.4% of pairs in Zones A + B (low risk of error). SEG analysis of hypoglycemia/hyperglycemia risk showed 92.22% of pairs in the "no risk" zone, 5.96% of pairs in the "slight lower" risk zone, 1.01% of pairs in the "slight higher" risk zone, and only 0.81% of pairs in the "moderate lower" risk zone.
conclusionsOverall performance of the Medtronic Enlite 2 CGM in the post-transplant population was reasonably good with "no risk" or "slight lower" risk by SEG analysis and high CGM-YSI agreement by CEG analysis; however, frequent recalibrations were required in this intensive care population.
Indexed as