ArticleMedical physics2017
The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.
Article in Medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Dependence of motion artifacts on the starting angle of projection data collection in a nonhelical volume scan of a 320-row CT.Physical and engineering sciences in medicine · 2026Article
- Sinogram-based flow estimation in computed tomography using a physics-informed neural network: Impact of gantry rotation speed, X-ray fluence and pulsed acquisition on accuracy.Medical physics · 2026Article
- Quantitative analysis of small coronary artery calcium detectability with an accurate simulation and validation on a clinical CT scanner.Medical physics · 2023Article
- DiFiR-CT: Distance field representation to resolve motion artifacts in computed tomography.Medical physics · 2023Article
- Four-dimensional computed tomography of the left ventricle, Part I: Motion artifact reduction.Medical physics · 2022Article
- Four-dimensional computed tomography of the left ventricle, Part II: Estimation of mechanical activation times.Medical physics · 2022Article
- Task-dependent estimability index to assess the quality of cardiac computed tomography angiography for quantifying coronary stenosis.Journal of medical imaging (Bellingham, Wash.) · 2021Article
- Motion-corrected coronary calcium scores by a convolutional neural network: a robotic simulating study.European radiology · 2020Article
- Precise measurement of coronary stenosis diameter with CCTA using CT number calibration.Medical physics · 2019Article
- Evaluation of motion artifact metrics for coronary CT angiography.Medical physics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeCoronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineation of vessels despite the presence of small motion. This simulation study characterizes the impact of small, uncorrected vessel drifts during data acquisition on the assessment of vessel intensity, diameter, and shape.
methodsWe developed a digital phantom and simulated projection data for a clinical scanner geometry for a range of vessel drifts that can occur during relative vessel stasis (0 to 2 mm per 360° gantry rotation) for vessels between 0.2 and 3.0 mm in diameter (covering 0% through 93% stenosis of a 3 mm vessel). In addition to the impact of vessel drift, we evaluated the performance of half-scan acquisitions (relative to full-scans) over a range of gantry positions. The performance of FDK reconstructions was compared to an iterative technique and potential improvement in sampling from focal spot deflection and quarter detector offset was compared.
resultsAt rest, vessel intensity and diameter were accurately obtained in vessels greater than 1.5 mm with all vessels appearing circular in shape (major-to-minor axis ratio ~1). Vessels between 1.5 and 0.2 mm in diameter demonstrated a rapid decrease in signal intensity with full width half maximum (FWHM) vessel diameters remaining above 0.75 mm as true vessel diameter decreased. Uncorrected vessel motion resulted in decreased vessel intensity, increased vessel diameter, and distortion of vessel shape. The extent of these changes depended on both the position of the gantry as well as the reconstruction approach (half- vs. full-scan). FDK reconstruction results depended on choice of filter with Ram-Lak results yielding comparable performance to an unconstrained iterative reconstruction. Focal spot deflection and quarter detector offset did not result in large changes in performance, likely due to the high sampling density near the isocenter.
conclusionsDespite improvement in gantry speed and acquisition of coronary images during cardiac phases that have relatively stationary vessels, small coronary drifts (0-2 mm per 360° rotation) have been reported and if uncorrected, can present challenges to visual grading and computational modeling of stenoses because vessels will appear dimmer, larger, and more ellipsoidal in shape. The impact of a particular motion depends on the gantry position, the use of half vs. full-scan acquisitions, and the reconstruction technique.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.