Trial reportLancet (London, England)2018
Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial.
Trial report in Lancet (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 229 papers, 10 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Real-Time Continuous Glucose Monitoring (RT-CGM) in Patients With Type 1 Diabetes at High Risk for Low Glucose Values Using Multiple Daily Injections (MDI) in Germany (HYPODE-STUDY)
Comparison of CGM in Non-randomised Real Life Study of Real-time and Intermittently Scanned Systems in Patients With Type 1 Diabetes
Who cites it
229 citing papers in PubMed, 10 syntheses or guidelines pooled it, 498 citations in OpenAlex.
- The therapeutic efficacy of continuous glucose monitoring in diabetes: an updated meta-analysis with meta-regression.Endocrine · 2025Pooled it
- 2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.Diabetes & metabolism journal · 2024Guideline
- Patient experiences of continuous glucose monitoring and sensor-augmented insulin pump therapy for diabetes: A systematic review of qualitative studies.Journal of diabetes · 2023Pooled it
- 2023 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association.Diabetes & metabolism journal · 2023Guideline
- Effect of divergent continuous glucose monitoring technologies on glycaemic control in type 1 diabetes mellitus: A systematic review and meta-analysis of randomised controlled trials.Diabetic medicine : a journal of the British Diabetic Association · 2022Pooled it
- Pooled it
- Effect of Different Glucose Monitoring Methods on Bold Glucose Control: A Systematic Review and Meta-Analysis.Computational and mathematical methods in medicine · 2022Pooled it
- 2021 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association.Diabetes & metabolism journal · 2021 · on this mapGuideline
- Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials.Acta diabetologica · 2021Pooled it
- Use of wearable biometric monitoring devices to measure outcomes in randomized clinical trials: a methodological systematic review.BMC medicine · 2020Pooled it
- Mulberry Twig Alkaloids Combined With Insulin Infusion: Effects on Blood Glucose Variability in Type 2 Diabetes.Medical science monitor : international medical journal of experimental and clinical research · 2026Trial
- The Effect of Do-It-Yourself Real-Time Continuous Glucose Monitoring on Glycemic Variables and Participant-Reported Outcomes in Adults With Type 1 Diabetes: A Randomized Crossover Trial.Journal of diabetes science and technology · 2025Trial
- Trial
- The Impact of Baseline User Characteristics on the Benefits of Real-Time Versus Intermittently Scanned Continuous Glucose Monitoring in Adults With Type 1 Diabetes: Moderator Analyses of the ALERTT1 Trial.Journal of diabetes science and technology · 2024Trial
- Trial
- Performance of the Glucose Management Indicator (GMI) in Type 2 Diabetes.Clinical chemistry · 2023Trial
- Evaluation of Clinical Metrics for Identifying Defective Physiologic Responses to Hypoglycemia in Long-Standing Type 1 Diabetes.Diabetes technology & therapeutics · 2022Trial
- Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts.Journal of diabetes science and technology · 2022Trial
- A parallel randomised controlled trial of the Hypoglycaemia Awareness Restoration Programme for adults with type 1 diabetes and problematic hypoglycaemia despite optimised self-care (HARPdoc).Nature communications · 2022Trial
- Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial.Diabetes care · 2020Trial
169 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals.
methodsThe HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTrials.gov, number NCT02671968.
findingsBetween March 4, 2016, and Jan 12, 2017, 149 participants were randomly assigned (n=74 to the control group; n=75 to the rtCGM group) and 141 completed the follow-up phase (n=66 in the control group, n=75 in the rtCGM group). The mean number of hypoglycaemic events per 28 days among participants in the rtCGM group was reduced from 10·8 (SD 10·0) to 3·5 (4·7); reductions among control participants were negligible (from 14·4 [12·4] to 13·7 [11·6]). Incidence of hypoglycaemic events decreased by 72% for participants in the rtCGM group (incidence rate ratio 0·28 [95% CI 0·20-0·39], p<0·0001). 18 serious adverse events were reported: seven in the control group, ten in the rtCGM group, and one before randomisation. No event was considered to be related to the investigational device.
interpretationUsage of rtCGM reduced the number of hypoglycaemic events in individuals with type 1 diabetes treated by MDI and with impaired hypoglycaemia awareness or severe hypoglycaemia.
fundingDexcom Inc.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.