ArticleBiosensors2018
Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus.
Article in Biosensors, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Influence of Anaerobic Exercise in Type 1 Diabetes Mellitus Biomarkers: ASystematic Review.Current diabetes reviews · 2024Pooled it
- Guideline
- Differences in Glucose Readings Between Right Arm and Left Arm Using a Continuous Glucose Monitor.Journal of diabetes science and technology · 2022Trial
- Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes.Diabetes technology & therapeutics · 2019Trial
- Safety and efficacy of continuous glucose monitoring devices in individuals with diabetes undergoing hyperbaric oxygen therapy: a scoping review.Diving and hyperbaric medicine · 2025Article
- Factory-Calibrated Continuous Glucose Monitoring System Accuracy During Exercise in Adolescents With Type 1 Diabetes Mellitus.Journal of diabetes science and technology · 2024Article
- Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.Journal of diabetes science and technology · 2023Article
- Flash glucose monitoring system in special situations.Archives of endocrinology and metabolism · 2022Review
- Accuracy of CGM Systems During Continuous and Interval Exercise in Adults with Type 1 Diabetes.Journal of diabetes science and technology · 2022Article
- Review
- Fault Tolerant Strategies for Automated Insulin Delivery Considering the Human Component: Current and Future Perspectives.Journal of diabetes science and technology · 2021Review
- Physical Activity, Dietary Patterns, and Glycemic Management in Active Individuals with Type 1 Diabetes: An Online Survey.International journal of environmental research and public health · 2021Article
- Responses to Low- and High-Intensity Exercise in Adolescents with Type 1 Diabetes in Relation to Their Level of VOInternational journal of environmental research and public health · 2021Article
- A Comprehensive Review of Continuous Glucose Monitoring Accuracy during Exercise Periods.Sensors (Basel, Switzerland) · 2021Review
- Accuracy of Flash Glucose Monitoring During Postprandial Rest and Different Walking Conditions in Overweight or Obese Young Adults.Frontiers in physiology · 2021Article
- Article
- Simple Post-Processing of Continuous Glucose Monitoring Measurements Improves Endpoints in Clinical Trials.Journal of diabetes science and technology · 2020Article
- Accuracy of the Dexcom G6 Glucose Sensor during Aerobic, Resistance, and Interval Exercise in Adults with Type 1 Diabetes.Biosensors · 2020Article
- Performance of the Eversense versus the Free Style Libre Flash glucose monitor during exercise and normal daily activities in subjects with type 1 diabetes mellitus.BMJ open diabetes research & care · 2020Observational
- GLU: a software package for analysing continuously measured glucose levels in epidemiology.International journal of epidemiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions and used two Medtronic Paradigm Enlite-2 sensors under closed-loop therapy. CGM readings were compared with plasma glucose during different periods: one hour before exercise, during exercise, and four hours after the end of exercise. In aerobic sessions, the median absolute relative difference (MARD) increased from 9.5% before the beginning of exercise to 16.5% during exercise (
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.