SynthesisThe Cochrane database of systematic reviews2018
Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.
Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 3 syntheses or guidelines pooled it, 42 citations in OpenAlex.
- Global Cancer Nurse's Experiences and Perceptions of Potential Occupational Exposure to Cytotoxic Drugs: Mixed Method Systematic Review With Framework Synthesis.Journal of clinical nursing · 2024Pooled it
- Exposure to Antineoplastic Drugs in Occupational Settings: A Systematic Review of Biological Monitoring Data.International journal of environmental research and public health · 2022Pooled it
- Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.The Cochrane database of systematic reviews · 2018Pooled it
- Occupational Reproductive Health Risks Among Women Healthcare Workers: A Narrative Review for Clinical Surveillance, Preconception Counseling, and Prevention.Journal of clinical medicine · 2026Review
- Safe Handling and Clinical Administration of Antibody Drug Conjugates: Occupational Safety, Material Compatibility, and the Integration of CSTDs into Workflows.AAPS PharmSciTech · 2026Review
- Cytotoxic Drug Handling Practices Among Pharmacy Technicians in Portugal: The Dig Deeper Study.Healthcare (Basel, Switzerland) · 2026Article
- Exploring the occupational protection potential of an intravenous compounding robot across the cytotoxic drug workflow.Frontiers in public health · 2026Article
- Adoption of Closed-System Drug Transfer Devices: Effectiveness in Reducing Occupational Exposure to Hazardous Drugs and the Change Management Process.The Canadian journal of hospital pharmacy · 2025Article
- Potential Sampling Errors in Stability Studies Due to Dead Volume in Closed System Transfer Devices.The Journal of pharmacy technology : jPT : official publication of the Association of Pharmacy Technicians · 2024Article
- Safe handling of cytostatic drugs: recommendations from independent science.European journal of hospital pharmacy : science and practice · 2024Article
- Article
- Integrity performance assessment of a closed system transfer device syringe adaptor lock as a terminal closure for Luer-Lock syringes.European journal of hospital pharmacy : science and practice · 2023Article
- Evaluation of the risk of occupational exposure to antineoplastic drugs in healthcare sector: part I - medical gloves.Arhiv za higijenu rada i toksikologiju · 2023Article
- Safe handling of hazardous drugs.Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners · 2023Article
- Closed-system transfer device use with oncology biologics: A survey of Canadian healthcare practitioners.Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners · 2022Article
- A simple approach to assess the cancer risk of occupational exposure to genotoxic drugs in healthcare settings.Journal of occupational medicine and toxicology (London, England) · 2022Article
- Occupational exposure to antineoplastic drugs: what about hospital sanitation personnel?International archives of occupational and environmental health · 2021Article
- Evaluation of a safe infusion device on reducing occupational exposure of nurses to antineoplastic drugs: a comparative prospective study. Contamoins-1.International archives of occupational and environmental health · 2021Article
- Review of economic data on closed system transfer drug for preparation and administration of hazardous drugs.European journal of hospital pharmacy : science and practice · 2020Review
- Advanced Medical Devices for Preparation and Administration of Chemotherapeutic Agents: Results from a Multi-Dimensional Evaluation.ClinicoEconomics and outcomes research : CEOR · 2020Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
6 authors at 5 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOccupational exposure to hazardous drugs can decrease fertility and result in miscarriages, stillbirths, and cancers in healthcare staff. Several recommended practices aim to reduce this exposure, including protective clothing, gloves, and biological safety cabinets ('safe handling'). There is significant uncertainty as to whether using closed-system drug-transfer devices (CSTD) in addition to safe handling decreases the contamination and risk of staff exposure to infusional hazardous drugs compared to safe handling alone.
objectivesTo assess the effects of closed-system drug-transfer of infusional hazardous drugs plus safe handling versus safe handling alone for reducing staff exposure to infusional hazardous drugs and risk of staff contamination. SEARCH
methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, OSH-UPDATE, CINAHL, Science Citation Index Expanded, economic evaluation databases, the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov to October 2017. SELECTION CRITERIA: We included comparative studies of any study design (irrespective of language, blinding, or publication status) that compared CSTD plus safe handling versus safe handling alone for infusional hazardous drugs. DATA COLLECTION AND ANALYSIS: Two review authors independently identified trials and extracted data. We calculated the risk ratio (RR) and mean difference (MD) with 95% confidence intervals (CI) using both fixed-effect and random-effects models. We assessed risk of bias according to the risk of bias in non-randomised studies of interventions (ROBINS-I) tool, used an intracluster correlation coefficient of 0.10, and we assessed the quality of the evidence using GRADE. MAIN
resultsWe included 23 observational cluster studies (358 hospitals) in this review. We did not find any randomised controlled trials or formal economic evaluations. In 21 studies, the people who used the intervention (CSTD plus safe handling) and control (safe handling alone) were pharmacists or pharmacy technicians; in the other two studies, the people who used the intervention and control were nurses, pharmacists, or pharmacy technicians. The CSTD used in the studies were PhaSeal (13 studies), Tevadaptor (1 study), SpikeSwan (1 study), PhaSeal and Tevadaptor (1 study), varied (5 studies), and not stated (2 studies). The studies' descriptions of the control groups were varied. Twenty-one studies provide data on one or more outcomes for this systematic review. All the studies are at serious risk of bias. The quality of evidence is very low for all the outcomes.There is no evidence of differences in the proportion of people with positive urine tests for exposure between the CSTD and control groups for cyclophosphamide alone (RR 0.83, 95% CI 0.46 to 1.52; I² = 12%; 2 studies; 2 hospitals; 20 participants; CSTD: 76.1% versus control: 91.7%); cyclophosphamide or ifosfamide (RR 0.09, 95% CI 0.00 to 2.79; 1 study; 1 hospital; 14 participants; CSTD: 6.4% versus control: 71.4%); and cyclophosphamide, ifosfamide, or gemcitabine (RR not estimable; 1 study; 1 hospital; 36 participants; 0% in both groups).There is no evidence of a difference in the proportion of surface samples contaminated in the pharmacy areas or patient-care areas for any of the drugs except 5-fluorouracil, which was lower in the CSTD group than in the control (RR 0.65, 95% CI 0.43 to 0.97; 3 studies, 106 hospitals, 1008 samples; CSTD: 9% versus control: 13.9%).The amount of cyclophosphamide was lower in pharmacy areas in the CSTD group than in the control group (MD -49.34 pg/cm², 95% CI -84.11 to -14.56, I² = 0%, 7 studies; 282 hospitals, 1793 surface samples). Additionally, one interrupted time-series study (3 hospitals; 342 samples) demonstrated a change in the slope between pre-CSTD and CSTD (3.9439 pg/cm², 95% CI 1.2303 to 6.6576; P = 0.010), but not between CSTD and post-CSTD withdrawal (-1.9331 pg/cm², 95% CI -5.1260 to 1.2598; P = 0.20). There is no evidence of difference in the amount of the other drugs between CSTD and control groups in the pharmacy areas or patient-care areas.None of the studies report on atmospheric contamination, blood tests, or other measures of exposure to infusional hazardous drugs such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, or micronuclei induction.None of the studies report short-term health benefits such as reduction in skin rashes, medium-term reproductive health benefits such as fertility and parity, or long-term health benefits related to the development of any type of cancer or adverse events.Five studies (six hospitals) report the potential cost savings through the use of CSTD. The studies used different methods of calculating the costs, and the results were not reported in a format that could be pooled via meta-analysis. There is significant variability between the studies in terms of whether CSTD resulted in cost savings (the point estimates of the average potential cost savings ranged from (2017) USD -642,656 to (2017) USD 221,818). AUTHORS'
conclusionsThere is currently no evidence to support or refute the routine use of closed-system drug transfer devices in addition to safe handling of infusional hazardous drugs, as there is no evidence of differences in exposure or financial benefits between CSTD plus safe handling versus safe handling alone (very low-quality evidence). None of the studies report health benefits.Well-designed multicentre randomised controlled trials may be feasible depending upon the proportion of people with exposure. The next best study design is interrupted time-series. This design is likely to provide a better estimate than uncontrolled before-after studies or cross-sectional studies. Future studies may involve other alternate ways of reducing exposure in addition to safe handling as one intervention group in a multi-arm parallel design or factorial design trial. Future studies should have designs that decrease the risk of bias and enable measurement of direct health benefits in addition to exposure. Studies using exposure should be tested for a relevant selection of hazardous drugs used in the hospital to provide an estimate of the exposure and health benefits of using CSTD. Steps should be undertaken to ensure that there are no other differences between CSTD and control groups, so that one can obtain a reasonable estimate of the health benefits of using CSTD.
Indexed as
Identifiers
What Socratic holds
Registered trials