Evidence map›Paper›PMID 29654444›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2020

Effect of reduced photon count levels and choice of normal data on semi-automated image assessment in cardiac SPECT.

Matthias Wetzl, James C Sanders, Torsten Kuwert, Philipp Ritt

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Personalization ofEJNMMI physics · 2023
    Article
  4. Effect of reduced photon count levels and choice of normal data on semi-automated image assessment in cardiac SPECT: Doing more with fewer counts.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  5. Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Review
  6. Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2019
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Matthias WetzlClinic of Nuclear Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054, Erlangen, Germany.
James C SandersClinic of Nuclear Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054, Erlangen, Germany.
Torsten KuwertClinic of Nuclear Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054, Erlangen, Germany.
Philipp RittClinic of Nuclear Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054, Erlangen, Germany. philipp.ritt@uk-erlangen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe SMARTZOOM multifocal collimator from Siemens Healthcare was developed to improve the γ-photon sensitivity in myocardial perfusion imaging without truncating the field of view. As part of the IQ-SPECT package, it may be used to reduce radiopharmaceutical dose to patients, as well as acquisition time. The aim of this study was twofold: (1) to evaluate the influence of dose reduction in semi-automated MPI scoring, with focus on different strategies for the choice of normal data (count-matched, full-count), and (2) to evaluate the effect of dose reduction afforded by Siemens' IQ-SPECT package.

methods50 patients underwent Tc-99m-sestamibi one-day stress/rest SPECT/CT. Multiple levels of count reduction were generated using binomial thinning. Using Corridor 4DM, summed stress score (SSS) was calculated using either count-matched or full-count normal data. Studies were classified as low-risk (SSS < 4) or intermediate/high-risk (SSS ≥ 4).

resultsCount reduction using count-matched normal data increases false-normal rate and decreases sensitivity. With full-count normal data, count reduction increases false-hypoperfusion rate, leading to decreased specificity. Altogether, rate of reclassification was significant at roughly 67% dose and below.

conclusionSignificant bias results from count level of normal data relative to actual patient data. Compared to standard LEHR, IQ-SPECT should allow for significant dose reduction.

Indexed as

Image Processing, Computer-AssistedMyocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonAgedAged, 80 and overCoronary Artery DiseaseExercise TestFemaleHumansMaleMiddle AgedRadiopharmaceuticalsRetrospective StudiesTechnetium Tc 99m SestamibiRadiopharmaceuticalsTechnetium Tc 99m Sestamibidose reductionMIBIMPInormal dataSPECT/CTTc-99m

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.