Evidence map›Paper›PMID 30203125›Full record

ReviewProgress in biomaterials2018

Cardiovascular stents: overview, evolution, and next generation.

Setareh Borhani, Shadi Hassanajili, Seyed Hossein Ahmadi Tafti, Shahram Rabbani

Open access · hybridAbstract readReview
In one paragraph

Review in Progress in biomaterials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 73 papers.

0numbers the graph read from it
0cells of the map it votes in
73citing papers in PubMed
18.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

73 citing papers in PubMed, 216 citations in OpenAlex.

  1. Trial
  2. Review
  3. Molecular phenotyping withEuropean journal of nuclear medicine and molecular imaging · 2026
    Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
  14. Review
  15. Metal-Organic Frameworks: Unlocking New Frontiers in Cardiovascular Diagnosis and Therapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Two-Staged Technology for CoCr Stent Production by SLM.Materials (Basel, Switzerland) · 2024
    Article

13 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Setareh BorhaniDepartment of Chemical Engineering, School of Chemical and Petroleum Engineering, Shiraz University, Shiraz, Iran.
Shadi HassanajiliDepartment of Nanochemical Engineering, School of New Science and Technology, Shiraz University, Shiraz, Iran. ajili@shirazu.ac.ir.
Seyed Hossein Ahmadi TaftiResearch Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences, North Kargar, Tehran, Iran.
Shahram RabbaniResearch Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences, North Kargar, Tehran, Iran.
Shiraz University · IRTehran University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Compared to bare-metal stents (BMSs), drug-eluting stents (DESs) have been regarded as a revolutionary change in coronary artery diseases (CADs). Releasing pharmaceutical agents from the stent surface was a promising progress in the realm of cardiovascular stents. Despite supreme advantages over BMSs, in-stent restenosis (ISR) and long-term safety of DESs are still deemed ongoing concerns over clinically application of DESs. The failure of DESs for long-term clinical use is associated with following factors including permanent polymeric coating materials, metallic stent platforms, non-optimal drug releasing condition, and factors that have recently been supposed as contributory factors such as degradation products of polymers, metal ions due to erosion and degradation of metals and their alloys utilizing in some stents as metal frameworks. Discovering the direct relation between stent materials and associating adverse effects is a complicated process, and yet it has not been resolved. For clinical success it is of significant importance to optimize DES design and explore novel strategies to overcome all problems including inflammatory response, delay endothelialization, and sub-acute stent thrombosis (ST) simultaneously. In this work, scientific reports are reviewed particularly focusing on recent advancements in DES design which covers both potential improvements of existing and recently novel prototype stent fabrications. Covering a wide range of information from the BMSs to recent advancement, this study mostly sheds light on DES's concepts, namely stent composition, drug release mechanism, and coating techniques. This review further reports different forms of DES including fully biodegradable DESs, shape-memory ones, and polymer-free DESs.

Indexed as

Cardiovascular stentsCoronary artery diseasesIn-stent restenosisStent thrombosis

Identifiers

PMID30203125
PMCPMC6173682
OpenAlexW2890924372

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.