Evidence map›Paper›PMID 30287826›Full record

ArticleScientific reports2018

Multi-Band Sensing for Dielectric Property of Chemicals Using Metamaterial Integrated Microfluidic Sensor.

Hong Zhou, Donglin Hu, Cheng Yang, Cong Chen, Junwang Ji, Ming Chen, Yu Chen, Ya Yang, Xiaojing Mu

Abstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Article
  11. Advanced DNA DetectionFrontiers in bioengineering and biotechnology · 2021
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hong ZhouInternational R & D center of Micro-nano Systems and New Materials Technology, Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, Chongqing University, Chongqing, 400044, China.
Donglin HuInternational R & D center of Micro-nano Systems and New Materials Technology, Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, Chongqing University, Chongqing, 400044, China.
Cheng YangDepartment of Clinical Laboratory Medicine, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing, 400042, China.
Cong ChenInternational R & D center of Micro-nano Systems and New Materials Technology, Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, Chongqing University, Chongqing, 400044, China.
Junwang JiInternational R & D center of Micro-nano Systems and New Materials Technology, Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, Chongqing University, Chongqing, 400044, China.
Ming ChenDepartment of Clinical Laboratory Medicine, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing, 400042, China. chming1971@126.com.
Yu ChenInstitute of High Performance Computing, Agency for Science, Technology and Research, Singapore, Singapore.
Ya YangBeijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, China. yayang@binn.cas.cn.
Xiaojing MuInternational R & D center of Micro-nano Systems and New Materials Technology, Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, Chongqing University, Chongqing, 400044, China. mxjacj@cqu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The growth of the chemical industry has brought tremendous challenges to chemical sensing technology. Chemical sensors based on metamaterials have great potential because of their label-free and non-destructive characteristics. However, metamaterials applied in chemical sensing have mainly been investigated from the measurement of sample concentration or the determination of the dielectric properties at a fixed frequency. Here we present a metamaterial integrated microfluidic (MIM) sensor for the multi-band sensing for dielectric property of chemicals, which is promising for the identification of chemicals. The MIM sensor mainly consists of multiple pair of high sensitive symmetrical double split-ring resonators (DSRRs) and meandering microfluidic channels with a capacity of only 4 μL. A dielectric model has been innovatively established and experimentally verified to accurately estimate the complex permittivity and thus realize the multi-band sensing of dielectric property of chemicals. With the increase in the number of resonators in the sensor, a dielectric spectrum like curve could be obtained for more detailed dielectric information. This work delivers a miniaturized, reusable, label-free and non-destructive metamaterial-microfluidic solution and paves a way of the multi-band sensing for dielectric property of chemicals.

Identifiers

PMID30287826
PMCPMC6172240

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.