Evidence map›Paper›PMID 30730229›Full record

ArticleJournal of diabetes science and technology2019

Performance and Usability of Three Systems for Continuous Glucose Monitoring in Direct Comparison.

Guido Freckmann, Manuela Link, Ulrike Kamecke, Cornelia Haug, Bernhard Baumgartner, Raimund Weitgasser

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Journal of diabetes science and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 35 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Analysis of Adverse Events in Medical Devices for Diabetes.Journal of diabetes science and technology · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Guido Freckmann1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.ORCID 0000-0002-0406-9529
Manuela Link1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Ulrike Kamecke1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Cornelia Haug1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Bernhard Baumgartner2 Abteilung für Innere Medizin / Kompetenzzentrum Diabetes, Privatklinik Wehrle-Diakonissen, Salzburg, Austria.
Raimund Weitgasser2 Abteilung für Innere Medizin / Kompetenzzentrum Diabetes, Privatklinik Wehrle-Diakonissen, Salzburg, Austria.
Universität Ulm · DESalzburger Landeskliniken · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo be able to compare continuous glucose monitoring (CGM) systems, they have to be worn in parallel by the same subjects. This study evaluated the performance and usability of three different CGM systems in direct comparison.

methodIn this open, prospective study at two sites, 54 patients with diabetes wore three CGM systems each (Dexcom G5™ Mobile CGM system [DG5], Guardian™ Connect system [GC], and a Roche CGM system [RCGM]) in parallel for 6 or 7 days in a mixed inpatient and outpatient setting. Capillary comparison measurements were performed using a self-monitoring of blood glucose (SMBG) system. During study site visits, glucose excursions were induced. Performance of the systems was evaluated by calculating mean absolute relative differences (MARD, calculated as absolute differences for glucose concentrations <100 mg/dL and as relative differences for glucose concentrations ≥100 mg/dL), and mean relative differences (MRD, bias) between CGM and SMBG results. In addition, usability of the systems was assessed.

resultsOverall MARD was 10.1 ± 2.1 for DG5, 11.5 ± 4.2 for GC, and 11.9 ± 5.6 for RCGM. Performance improved in all systems after the first day of use. All systems showed >99% of values within zones A and B of the consensus error grid. Overall, all CGM systems showed a small negative bias compared to SMBG. Usability of the systems differed regarding patch adhesion rate, failure rate, and patient rating. Most patients preferred GC, but in general all systems were rated positively.

conclusionAll three CGM systems showed similar overall accuracy in this direct comparison, but small differences were observed with regard to specific glucose ranges and usability aspects.

Indexed as

AdultBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2FemaleHumansMaleMiddle AgedBlood GlucoseCGM systemcomparison studycontinuous glucose monitoringMARDperformanceusability

Identifiers

PMID30730229
PMCPMC6955463
OpenAlexW2911681618

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.