Trial reportThe Journal of clinical endocrinology and metabolism2020
A Randomized, Placebo-Controlled Double-Blind Trial of a Closed-Loop Glucagon System for Postbariatric Hypoglycemia.
Trial report in The Journal of clinical endocrinology and metabolism, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03255629 (Closed-Loop Glucagon Pump for Treatment of Post-Bariatric Hypoglycemia), which is not on this map. Cited by 19 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Closed-Loop Glucagon Pump for Treatment of Post-Bariatric Hypoglycemia
Who cites it
19 citing papers in PubMed, 1 synthesis or guideline pooled it, 41 citations in OpenAlex.
- European guideline on obesity care in patients with gastrointestinal and liver diseases - Joint European Society for Clinical Nutrition and Metabolism / United European Gastroenterology guideline.United European gastroenterology journal · 2022Guideline
- Post-bariatric hypoglycaemia: from altered gut physiology to targeted therapies.Endocrine connections · 2026Article
- Dysregulated glucagon signaling contributes to hypoglycemia after vertical sleeve gastrectomy in mice.Molecular metabolism · 2026Article
- Post-bariatric Hypoglycemia Management: A Gulf Cooperation Council Consensus Statement.Journal of the Endocrine Society · 2026Article
- A personalized and automated real-time meal detection algorithm based on continuous glucose monitoring and heart rate data for individuals with post-bariatric hypoglycemia.Frontiers in digital health · 2026Article
- Managing post-bariatric hypoglycemia: a systematic review of pharmacological therapies.Diabetology & metabolic syndrome · 2025Article
- Modeling Meal Absorption in Subjects Post-Roux-en-Y Gastric Bypass Surgery Leading to Post-Bariatric Hypoglycemia.Control Technology and Applications. Control Technology and Applications · 2025Article
- Bariatric surgery and diabetes: Current challenges and perspectives.World journal of diabetes · 2024Review
- Society for Endocrinology guidelines for the diagnosis and management of post-bariatric hypoglycaemia.Endocrine connections · 2024Review
- Hypoglycemia post bariatric surgery: drugs with different mechanisms of action to treat a unique disorder.Archives of endocrinology and metabolism · 2023Review
- Glucose metabolism after bariatric surgery: implications for T2DM remission and hypoglycaemia.Nature reviews. Endocrinology · 2023Review
- Forecasting postbariatric hypoglycaemia in patients after Roux-en-Y gastric bypass using model-based algorithms fed by continuous glucose monitoring data: A proof-of-concept study.Diabetes, obesity & metabolism · 2022Article
- Treating an Unconscious Patient With Diabetes Wearing a Device Attached to Their Body.Journal of diabetes science and technology · 2022Article
- Beyond diabetes remission a step further: Post bariatric surgery hypoglycemia.World journal of diabetes · 2022Article
- Glycemic Patterns Are Distinct in Post-Bariatric Hypoglycemia After Gastric Bypass (PBH-RYGB).The Journal of clinical endocrinology and metabolism · 2021Article
- A Potential Role for Endogenous Glucagon in Preventing Post-Bariatric Hypoglycemia.Frontiers in endocrinology · 2020Article
- Hypoglycemia After Upper Gastrointestinal Surgery: Clinical Approach to Assessment, Diagnosis, and Treatment.Diabetes, metabolic syndrome and obesity : targets and therapy · 2020Review
- Diagnosis and Management of Post-Bariatric Hypoglycemia.Journal of the American Board of Family Medicine : JABFMReview
- Regarding a successful treatment with artificial pancreas for a patient who attempted suicide using a high-dose insulin s.c. injection.Acute medicine & surgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundPostbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective.
methodsPatients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose monitor (CGM, Dexcom) driving a patch infusion pump (Insulet) filled with liquid investigational glucagon (Xeris) or placebo (vehicle). Sensor/plasma glucose responses to mixed meal were assessed during 2 study visits. The system delivered up to 2 doses of study drug (300/150 μg glucagon or equal-volume vehicle) if triggered by the algorithm. Rescue dextrose was given for plasma glucose <55 mg/dL or neuroglycopenia.
resultsTwelve participants (11 females/1 male, age 52 ± 2, 8 ± 1 years postsurgery, mean ± SEM) completed all visits. Predictive hypoglycemia alerts prompted automated drug delivery postmeal, when sensor glucose was 114 ± 7 vs 121 ± 5 mg/dL (P = .39). Seven participants required rescue glucose after vehicle but not glucagon (P = .008). Five participants had severe hypoglycemia (<55 mg/dL) after vehicle but not glucagon (P = .03). Nadir plasma glucose was higher with glucagon vs vehicle (67 ± 3 vs 59 ± 2 mg/dL, P = .004). Plasma glucagon rose after glucagon delivery (1231 ± 187 vs 16 ± 1 pg/mL at 30 minutes, P = .001). No rebound hyperglycemia occurred. Transient infusion site discomfort was reported with both glucagon (n = 11/12) and vehicle (n = 10/12). No other adverse events were observed.
conclusionA CGM-guided closed-loop rescue system can detect imminent hypoglycemia and deliver glucagon, reducing severe hypoglycemia in PBH. CLINICAL TRIALS REGISTRATION: NCT03255629.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.