The utility of heart-to-mediastinum ratio using a planar image created from IQ-SPECT with Iodine-123 meta-iodobenzylguanidine.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- The prognostic value ofJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022Pooled it
- Are nuclear medicine images quantified in 2D and 3D equally functional?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Article
- Lung-to-heart ratio analysis using virtual planar images obtained from myocardial perfusion SPECT data: A phantom and clinical studies.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Article
- Performance evaluation of a novel multi-pinhole collimator on triple-NaI-detector SPECT/CT for dedicated myocardial imaging.EJNMMI physics · 2023Article
- Phantom-Based Standardization Method forAnnals of nuclear cardiology · 2023Article
- Methods of calculatingAnnals of nuclear medicine · 2022Article
- Functional innervation imaging in the evaluation of cardiotoxicity: Just the beginning of the journey.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022Article
- Left ventricular hypertrophy caused by arterial hypertension and degenerative aortic stenosis: How usefulJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022Article
- TheJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aims
methodsThe planar image and transverse images of IQ-SPECT with attenuation and scatter corrections (ACSC) and without ACSC (NC) were obtained. Multi-planar reconstruction and ray-summation processing were applied to create IQ-planar images with NC and ACSC. Linear regression between the measured HMR from the planar image and the mathematically calculated HMR was used to calibrate HMR to standardized values.
resultsScatterplots and linear regression lines between planar and IQ-planar HMRs before and after cross-calibration showed systematic differences in both NC and ACSC conditions. The IQ-planar HMR with NC and ACSC was significantly higher compared with that of the conventional planar image. However, the IQ-planar HMR with NC and ACSC after cross-calibration was similar to the standardized HMR calculated by planar image.
conclusionThe IQ-planar HMR using the new ray-summation processing method could be used along with the conventional planar HMR.