Evidence map›Paper›PMID 32206405›Full record

ArticleBiomedical optics express2020

Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Oscar Caravaca Mora, Philippe Zanne, Lucile Zorn, Florent Nageotte, Natalia Zulina, Sara Gravelyn, Paul Montgomery, Michel de Mathelin, Bernard Dallemagne, Michalina J Gora

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. OCT-based intra-cochlear imaging and 3D reconstruction: ex vivo validation of a robotic platform.International journal of computer assisted radiology and surgery · 2024
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 3 countries.

Oscar Caravaca MoraICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.ORCID https://orcid.org/0000-0002-4617-2671
Philippe ZanneICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Lucile ZornICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Florent NageotteICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Natalia ZulinaICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Sara GravelynICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Paul MontgomeryICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Michel de MathelinICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Bernard DallemagneIRCAD - Hôpitaux Universitaires - 1, place de l'Hôpital - 67091 Strasbourg Cedex, France.
Michalina J GoraICube Laboratory, CNRS, Strasbourg University, 4, rue Kirschleger - 67085 Strasbourg Cedex, France.
Centre National de la Recherche Scientifique · FRInstitut de Recherche contre les Cancers de l’Appareil Digestif · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

When detected early, colorectal cancer can be treated with minimally invasive flexible endoscopy. However, since only specialized experts can delineate margins and perform endoscopic resections of lesions, patients still often undergo colon resections. To better assist in the performance of surgical tasks, a robotized flexible interventional endoscope was previously developed, having two additional side channels for surgical instrument. We propose to enhance the imaging capabilities of this device by combining it with optical coherence tomography (OCT). For this purpose, we have developed a new steerable OCT instrument with an outer diameter of 3.5 mm. The steerable instrument is terminated with a 2 cm long transparent sheath to allow three-dimensional OCT imaging using a side-focusing optical probe with two external scanning actuators. The instrument is connected to an OCT imaging system built around the OCT Axsun engine, with a 1310 nm center wavelength swept source laser and 100 kHz A-line rate. Once inserted in one of the side channels of the robotized endoscope, bending, rotation and translation of the steerable OCT instrument can be controlled by a physician using a joystick. Ex vivo and in vivo tests show that the novel, steerable and teleoperated OCT device enhances dexterity, allowing for inspection of the surgical field without the need for changing the position of the main endoscope.

Identifiers

PMID32206405
PMCPMC7075597
OpenAlexW2997798741

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.