Evidence map›Paper›PMID 32215877›Full record

ArticleApplied health economics and health policy2021

Cardiac Resynchronisation Therapy in Patients with Moderate to Severe Heart Failure in Germany: A Cost-Utility Analysis of the Additional Defibrillator.

Moritz Hadwiger, Fabian-Simon Frielitz, Nora Eisemann, Christian Elsner, Nikolaos Dagres, Gerhard Hindricks, Alexander Katalinic

Abstract read
In one paragraph

Article in Applied health economics and health policy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Infections associated with cardiac electronic implantable devices: economic perspectives and impact of the TYRX™ antibacterial envelope.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Moritz HadwigerInstitute of Social Medicine and Epidemiology, University of Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany. moritz.hadwiger@uksh.de.
Fabian-Simon FrielitzInstitute of Social Medicine and Epidemiology, University of Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany.
Nora EisemannInstitute of Social Medicine and Epidemiology, University of Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany.
Christian ElsnerInstitute of Social Medicine and Epidemiology, University of Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany.
Nikolaos DagresHeart Center Leipzig, University of Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
Gerhard HindricksHeart Center Leipzig, University of Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
Alexander KatalinicInstitute of Social Medicine and Epidemiology, University of Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiac resynchronisation therapy (CRT) is a well-established form of treatment for patients with heart failure and cardiac dyssynchrony. There are two different types of CRT devices: the biventricular pacemaker (CRT-P) and the biventricular defibrillator (CRT-D). The latter is more complex but also more expensive. For the majority of patients who are eligible for CRT, both devices are appropriate according to current guidelines. The purpose of this study was to conduct a cost-utility analysis for CRT-D compared to CRT-P from a German payer's perspective.

methodsA cohort Markov-model was developed to assess average costs and quality-adjusted life-years (QALY) for CRT-D and CRT-P. The model consisted of six stages: one for the device implementation, one for the absorbing state death, and two stages ("Stable" and "Hospital") for either a CRT device or medical therapy. The time horizon was 20 years. Deterministic and probabilistic sensitivity analyses and scenario analyses were conducted.

resultsThe incremental cost-effectiveness ratio (ICER) of CRT-D compared with CRT-P was €24,659 per additional QALY gained. In deterministic sensitivity analysis, the survival advantage of CRT-D to CRT-P was the most influential input parameter. In the probabilistic sensitivity analysis 96% of the simulated cases were more effective but also more costly.

conclusionsTherapy with CRT-D compared to CRT-P resulted in an additional gain of QALYs, but was more expensive. In addition, the ICER was subject to uncertainty, especially due to the uncertainty in the survival benefit. A randomised controlled trial and subgroup analyses would be desirable to further inform decision making.

Indexed as

Cardiac Resynchronization TherapyHeart FailureCost-Benefit AnalysisDefibrillatorsHumansQuality-Adjusted Life Years

Identifiers

PMID32215877
PMCPMC7790776

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.