Evidence map›Paper›PMID 32232090›Full record

ReviewBioelectronic medicine2018

Automated closed-loop control of diabetes: the artificial pancreas.

Boris Kovatchev

Open access · goldAbstract readReview
In one paragraph

Review in Bioelectronic medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
5.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 75 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Editorial: Technologies for diabetes, volume III.Frontiers in endocrinology · 2026
    Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Review
  15. Examining Type 1 Diabetes Mathematical Models Using Experimental Data.International journal of environmental research and public health · 2022
    Article
  16. Article
  17. Powering Implantable and Ingestible Electronics.Advanced functional materials · 2021
    Article
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Boris KovatchevCenter for Diabetes Technology, University of Virginia, P.O. Box 400888, Charlottesville, VA 22908 USA.ORCID 0000-0003-0495-3901
University of Virginia · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The incidence of Diabetes Mellitus is on the rise worldwide, which exerts enormous health toll on the population and enormous pressure on the healthcare systems. Now, almost hundred years after the discovery of insulin in 1921, the optimization problem of diabetes is well formulated as maintenance of strict glycemic control without increasing the risk for hypoglycemia. External insulin administration is mandatory for people with type 1 diabetes; various medications, as well as basal and prandial insulin, are included in the daily treatment of type 2 diabetes. This review follows the development of the Diabetes Technology field which, since the 1970s, progressed remarkably through continuous subcutaneous insulin infusion (CSII), mathematical models and computer simulation of the human metabolic system, real-time continuous glucose monitoring (CGM), and control algorithms driving closed-loop control systems known as the "artificial pancreas" (AP). All of these developments included significant engineering advances and substantial bioelectronics progress in the sensing of blood glucose levels, insulin delivery, and control design. The key technologies that enabled contemporary AP systems are CSII and CGM, both of which became available and sufficiently portable in the beginning of this century. This powered the quest for wearable home-use AP, which is now under way with prototypes tested in outpatient studies during the past 6 years. Pivotal trials of new AP technologies are ongoing, and the first hybrid closed-loop system has been approved by the FDA for clinical use. Thus, the closed-loop AP is well on its way to become the digital-age treatment of diabetes.

Indexed as

Artificial pancreas (AP)Closed-loop controlContinuous glucose monitoring (CGM)Continuous subcutaneous insulin infusion (CSII)DiabetesHyperglycemiaHypoglycemiaInsulin pumps

Identifiers

PMID32232090
PMCPMC7098217
OpenAlexW2899547006

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.