Evidence map›Paper›PMID 32355749›Full record

ArticleAnnals of translational medicine2020

Robotic assisted nephrectomy for living kidney donation (RANLD) with use of multiple locking clips or ligatures for renal vascular closure.

Maximilian Brunotte, Sebastian Rademacher, Justine Weber, Elisabeth Sucher, Andri Lederer, Hans-Michael Hau, Jens-Uwe Stolzenburg, Daniel Seehofer, Robert Sucher

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Maximilian BrunotteDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Sebastian RademacherDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Justine WeberDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Elisabeth SucherDepartment of Gastroenterology, Division of Hepatology, University Hospital of Leipzig, Leipzig, Germany.
Andri LedererDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Hans-Michael HauDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Jens-Uwe StolzenburgDepartment of Urology, University Hospital of Leipzig, Leipzig, Germany.
Daniel SeehoferDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
Robert SucherDepartment of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital of Leipzig, Leipzig, Germany.
University Hospital Leipzig · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRobotic assisted nephrectomy for living donation (RANLD) is a rapid emerging surgical technique competing for supremacy with totally laparoscopic and laparoscopic hand assisted techniques. Opinions about the safety of specific techniques of vascular closure in minimally invasive living kidney donation are heterogeneous and may be different for laparoscopic and robotic assisted surgical techniques.

methodsWe retrospectively analyzed perioperative and short-term outcomes of our first (n=40) RANLD performed with the da Vinci Si surgical platform. Vascular closure of renal vessels was performed by either double clipping or a combination of clips and non-transfixing suture ligatures.

resultsRANLD almost quintupled in our center for the observed time period. A total of n=21 (52.5%) left and n=19 (47.5%) right kidneys were procured. Renal vessel sealing with two locking clips was performed in 18 cases (45%) Both, clips and non-transfixing ligatures were used in 22 cases (55%). Mean donor age was 53.075±11.68 years (range, 28-70). The average total operative time was 150.75±27.30 min. Right donor nephrectomy (139±22 min) was performed significantly faster than left (160.95±27.93 min, P=0.01). Warm ischemia time was similar for both vascular sealing techniques and did not differ between left and right nephrectomies. No conversion was necessary. Clavien-Dindo Grade ≤IIIb complications occurred in (n=5) 12.5%. Grade IV and V complications did not develop. In particular no hemorrhage occurred using multiple locking clips or suture ligatures for renal vascular closure. Mortality was 0%. Thirteen kidneys (32.5%) were transplanted across the AB0 barrier.

conclusionsRANLD is an emerging minimally invasive surgical technique which facilitates excellent perioperative and short-term outcomes also when using multiple locking clips or suture ligatures for renal vascular closure.

Indexed as

Kidney transplantationlaparoscopic donor nephrectomyrenal allograftrobotic surgery

Identifiers

PMID32355749
PMCPMC7186662
OpenAlexW3008700923

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.