ArticleJournal of clinical hypertension (Greenwich, Conn.)2020
Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range.
Article in Journal of clinical hypertension (Greenwich, Conn.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range.Journal of clinical hypertension (Greenwich, Conn.) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Automated office blood pressure measurement eliminates the white coat effect and is associated with awake ambulatory blood pressure. This study examined whether automated office blood pressure values at lower limits were comparable to those of awake and mean 24-hour ambulatory blood pressure. A total of 552 patients were included in the study, involving 293 (53.1%) men and 259 (46.9%) women, with a mean age 55.0 ± 12.5, of whom 36% were treated for hypertension. Both systolic and diastolic automated office blood pressures exhibited lower values compared to awake ambulatory blood pressure among 254 individuals with systolic automated office blood pressure <130 mm Hg (119 ± 8 mm Hg vs 125 ± 11 mm Hg, P < .0001 and 75 ± 9 mm Hg vs 79 ± 9 mm Hg, P < .0001 for systolic and diastolic BPs, respectively). Furthermore, the comparison of systolic automated office blood pressure to the mean 24-hour ambulatory blood pressure levels also showed lower values (119 ± 8 vs 121 ± 10, P = .007), whereas the diastolic automated office blood pressure measurements were similar to 24-hour ambulatory blood pressure values. Our findings show that when automated office blood pressure readings express values <130/80 mm Hg in repeated office visits, further investigation should be performed only when masked hypertension is suspected; otherwise, higher automated office blood pressure values could be used for the diagnosis of uncontrolled hypertension, especially in individuals with organ damage.