Evidence map›Paper›PMID 32709239›Full record

ArticleBiomedical engineering online2020

Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study.

Karina Berner, John Cockcroft, Quinette Louw

Open access · goldAbstract readValidation Study
In one paragraph

Article in Biomedical engineering online, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Karina BernerDivision of Physiotherapy, Faculty of Medicine and Health Sciences, Stellenbosch University, PO Box 241, Cape Town, 8000, South Africa. kberner@sun.ac.za.ORCID http://orcid.org/0000-0002-2255-371X
John CockcroftCentral Analytical Facilities, Neuromechanics Unit, Stellenbosch University, Private Bag X1, Matieland, 7602, South Africa.
Quinette LouwDivision of Physiotherapy, Faculty of Medicine and Health Sciences, Stellenbosch University, PO Box 241, Cape Town, 8000, South Africa.
Stellenbosch University · ZA

Funding

Harry Crossley Foundation SU-PT-15/10-000005Harry Crossley Foundation SU-PT-16/10- 000057South African Medical Research Council National Health Scholars ProgrammeSouth African Medical Research Council Self-Initiated Research Grant
6 · The paper itself

Abstract

backgroundInertial measurement unit (IMU)-based motion capture systems are gaining popularity for gait analysis outside laboratories. It is important to determine the performance of such systems in specific patient populations. We aimed to validate and determine within-day reliability of an IMU system for measuring lower limb gait kinematics and temporal-spatial parameters (TSP) in people with and without HIV.

methodsGait was recorded in eight adults with HIV (PLHIV) and eight HIV-seronegative participants (SNP), using IMUs and optical motion capture (OMC) simultaneously. Participants performed six gait trials. Fifteen TSP and 28 kinematic angles were extracted. Intraclass correlations (ICC), root-mean-square error (RMSE), mean absolute percentage error and Bland-Altman analyses were used to assess concurrent validity of the IMU system (relative to OMC) separately in PLHIV and SNP. IMU reliability was assessed during within-session retest of trials. ICCs were used to assess relative reliability. Standard error of measurement (SEM) and percentage SEM were used to assess absolute reliability.

resultsBetween-system TSP differences demonstrated acceptable-to-excellent ICCs (0.71-0.99), except for double support time and temporophasic parameters (< 0.60). All TSP demonstrated good mean absolute percentage errors (≤7.40%). For kinematics, ICCs were acceptable to excellent (0.75-1.00) for all but three range of motion (ROM) and four discrete angles. RMSE and bias were 0.0°-4.7° for all but two ROM and 10 discrete angles. In both groups, TSP reliability was acceptable to excellent for relative (ICC 0.75-0.99) (except for one temporal and two temporophasic parameters) and absolute (%SEM 1.58-15.23) values. Reliability trends of IMU-measured kinematics were similar between groups and demonstrated acceptable-to-excellent relative reliability (ICC 0.76-0.99) and clinically acceptable absolute reliability (SEM 0.7°-4.4°) for all but two and three discrete angles, respectively. Both systems demonstrated similar magnitude and directional trends for differences when comparing the gait of PLHIV with that of SNP.

conclusionsIMU-based gait analysis is valid and reliable when applied in PLHIV; demonstrating a sufficiently low precision error to be used for clinical interpretation (< 5° for most kinematics; < 20% for TSP). IMU-based gait analysis is sensitive to subtle gait deviations that may occur in PLHIV.

Indexed as

Gait AnalysisMechanical PhenomenaSpatio-Temporal AnalysisAdultBiomechanical PhenomenaFemaleHIV InfectionsHumansMaleGait analysisHIV infectionInertial measurement unitsInertial motion captureKinematicsMeasurement errorReliabilityTemporospatial parametersValidity

Identifiers

PMID32709239
PMCPMC7379351
OpenAlexW3045334767

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.