ArticleBiomedical engineering online2020
Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study.
Article in Biomedical engineering online, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 21 citations in OpenAlex.
- Novel magnetometer-free inertial-measurement-unit-based orientation estimation approach for measuring upper limb kinematics.Wearable technologies · 2025Article
- Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review.Diagnostics (Basel, Switzerland) · 2024Review
- Dynamic Alignment Changes of the Spine, Pelvis, and Lower Limbs during Gait Analyzed Using Inertial Motion Capture in Patients with Adult Spinal Deformity.Spine surgery and related research · 2024Article
- A Novel Method and System Implementation for Precise Estimation of Single-Axis Rotational Angles.Sensors (Basel, Switzerland) · 2024Article
- Daily walking kinematic characteristics of the elderly in different residential settings: experimental study on Chinese community-living elderly and long-term nursing home residents.Aging clinical and experimental research · 2023Article
- Changes in Coordination and Its Variability with an Increase in Functional Performance of the Lower Extremities.Biosensors · 2023Article
- Robot-Assisted Ankle Rehabilitation Using the Hybrid Assistive Limb for Children after Equinus Surgery: A Report of Two Cases.Pediatric reports · 2022Article
- The Effect of Inclines on Joint Angles in Stroke Survivors During Treadmill Walking.Frontiers in neurology · 2022Article
- Mobility Deviations in Adults With Human Immunodeficiency Virus: A Cross-Sectional Assessment Using Gait Analysis, Functional Performance, and Self-Report.Open forum infectious diseases · 2021Article
- Detection of Movement Events of Long-Track Speed Skating Using Wearable Inertial Sensors.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
backgroundInertial measurement unit (IMU)-based motion capture systems are gaining popularity for gait analysis outside laboratories. It is important to determine the performance of such systems in specific patient populations. We aimed to validate and determine within-day reliability of an IMU system for measuring lower limb gait kinematics and temporal-spatial parameters (TSP) in people with and without HIV.
methodsGait was recorded in eight adults with HIV (PLHIV) and eight HIV-seronegative participants (SNP), using IMUs and optical motion capture (OMC) simultaneously. Participants performed six gait trials. Fifteen TSP and 28 kinematic angles were extracted. Intraclass correlations (ICC), root-mean-square error (RMSE), mean absolute percentage error and Bland-Altman analyses were used to assess concurrent validity of the IMU system (relative to OMC) separately in PLHIV and SNP. IMU reliability was assessed during within-session retest of trials. ICCs were used to assess relative reliability. Standard error of measurement (SEM) and percentage SEM were used to assess absolute reliability.
resultsBetween-system TSP differences demonstrated acceptable-to-excellent ICCs (0.71-0.99), except for double support time and temporophasic parameters (< 0.60). All TSP demonstrated good mean absolute percentage errors (≤7.40%). For kinematics, ICCs were acceptable to excellent (0.75-1.00) for all but three range of motion (ROM) and four discrete angles. RMSE and bias were 0.0°-4.7° for all but two ROM and 10 discrete angles. In both groups, TSP reliability was acceptable to excellent for relative (ICC 0.75-0.99) (except for one temporal and two temporophasic parameters) and absolute (%SEM 1.58-15.23) values. Reliability trends of IMU-measured kinematics were similar between groups and demonstrated acceptable-to-excellent relative reliability (ICC 0.76-0.99) and clinically acceptable absolute reliability (SEM 0.7°-4.4°) for all but two and three discrete angles, respectively. Both systems demonstrated similar magnitude and directional trends for differences when comparing the gait of PLHIV with that of SNP.
conclusionsIMU-based gait analysis is valid and reliable when applied in PLHIV; demonstrating a sufficiently low precision error to be used for clinical interpretation (< 5° for most kinematics; < 20% for TSP). IMU-based gait analysis is sensitive to subtle gait deviations that may occur in PLHIV.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.