Evidence map›Paper›PMID 32767865›Full record

ArticleKorean journal of radiology2020

Contrast-Enhanced High-Resolution Intracranial Vessel Wall MRI with Compressed Sensing: Comparison with Conventional T1 Volumetric Isotropic Turbo Spin Echo Acquisition Sequence.

Chae Jung Park, Jihoon Cha, Sung Soo Ahn, Hyun Seok Choi, Young Dae Kim, Hyo Suk Nam, Ji Hoe Heo, Seung Koo Lee

Abstract read
In one paragraph

Article in Korean journal of radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chae Jung ParkDepartment of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0002-5567-8658
Jihoon ChaDepartment of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea. JIHOONCHA@yuhs.ac.ORCID 0000-0002-1662-8041
Sung Soo AhnDepartment of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0002-0503-5558
Hyun Seok ChoiDepartment of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0003-4999-8513
Young Dae KimDepartment of Neurology, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0001-5750-2616
Hyo Suk NamDepartment of Neurology, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0002-4415-3995
Ji Hoe HeoDepartment of Neurology, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0001-9898-3321
Seung Koo LeeDepartment of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0001-5646-4072

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveCompressed sensing (CS) has gained wide interest since it accelerates MRI acquisition. We aimed to compare the 3D post-contrast T1-weighted volumetric isotropic turbo spin echo acquisition (VISTA) with CS (VISTA-CS) and without CS (VISTA-nonCS) in intracranial vessel wall MRIs (VW-MRI). MATERIALS AND

methodsFrom April 2017 to July 2018, 72 patients who underwent VW-MRI, including both VISTA-CS and VISTA-nonCS, were retrospectively enrolled. Wall and lumen volumes, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured from normal and lesion sites. Two neuroradiologists independently evaluated overall image quality and degree of normal and lesion wall delineation with a four-point scale (scores ≥ 3 defined as acceptable).

resultsScan coverage was increased in VISTA-CS to cover both anterior and posterior circulations with a slightly shorter scan time compared to VISTA-nonCS (approximately 7 minutes vs. 8 minutes). Wall and lumen volumes were not significantly different with VISTA-CS or VISTA-nonCS (interclass correlation coefficient = 0.964-0.997). SNR was or trended towards significantly higher values in VISTA-CS than in VISTA-nonCS. At normal sites, CNR was not significantly different between two sequences (

conclusionCS may be useful for intracranial VW-MRI as it allows for larger scan coverage with slightly shorter scan time without compromising image quality.

Indexed as

AdultAgedCarotid ArteriesContrast MediaFemaleHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedMiddle Cerebral ArteryRetrospective StudiesSignal-To-Noise RatioVertebral ArteryContrast MediaAccelerationBlood vesselsDiagnostic imagingMagnetic resonance imagingSignal-to-noise ratio

Identifiers

PMID32767865
PMCPMC7689147

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.