ArticleSensors (Basel, Switzerland)2020
Simplified Approach to Detect Dielectric Constant Using a Low-Cost Microfluidic Quarter Mode Substrate-Integrated Waveguide.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 7 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Liquid materials' characterization using commercial probes and radio frequency techniques is expensive and complex. This study proposes a compact and cost-effective radio frequency sensor system to measure the dielectric constant using a three-material calibration. The simplified approach measures reflection coefficient magnitudes for all four materials rather than the complex values in conventional permittivity detection systems. We employ a sensor module based on a circular substrate-integrated waveguide with measured unloaded quality factor = 910 to ensure measurement reliability. Miniaturized quarter-mode substrate-integrated waveguide resonators are integrated with four microfluidic channels containing three known materials and one unknown analyte. Step-wise measurement and linearity ensures maximum 4% error for the dielectric constant compared with results obtained using a high-performance commercial product.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.