Evidence map›Paper›PMID 33110134›Full record

ArticleScientific reports2020

Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults.

Yeon Jin Cho, Woo Sun Kim, Young Hun Choi, Seul Bi Lee, SeungHyun Lee, Jung-Eun Cheon, MunYoung Paek, SeungTae Woo

Open access · goldAbstract readValidation Study
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. A signal model for fat-suppressed TNMR in biomedicine · 2025
    Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Yeon Jin ChoDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Woo Sun KimDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. kimws@snu.ac.kr.
Young Hun ChoiDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Seul Bi LeeDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
SeungHyun LeeDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Jung-Eun CheonDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
MunYoung PaekSiemens Healthcare Ltd., 23, Chungjeong-ro, Seodaemun-gu, Seoul, 03737, Republic of Korea.
SeungTae WooRadiology, Bayer Korea Ltd., 23, Boramae-ro, Dongjak-gu, Seoul, 07071, Republic of Korea.
Seoul National University Hospital · KRBayer (South Korea) · KRSeoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We investigated the feasibility of free-breathing modified Look-Locker inversion recovery (MOLLI) sequence for measuring hepatic T1 values in children and young adults. To investigate the accuracy and the reproducibility of the T1 maps, a phantom study was performed with 12 different gadoterate meglumine concentrations and the T1 relaxation times of phantoms measured with the MOLLI sequence were compared against those measured with three different sequences: spin-echo inversion recovery, variable flip angle (VFA), and VFA with B1 correction. To evaluate the feasibility of free-breathing MOLLI sequence, hepatic T1 relaxation times obtained by free-breathing and breath-hold technique in twenty patients were compared. The phantom study revealed the excellent accuracy and reproducibility of MOLLI. In twenty patients, the mean value of hepatic T1 values obtained by free-breathing (606.7 ± 64.5 ms) and breath-hold (609.8 ± 64.0 ms) techniques showed no significant difference (p > 0.05). The Bland-Altman plot between the free-breathing and breath-hold revealed that the mean difference of T1 values was - 3.0 ms (- 0.5%). Therefore, T1 relaxation times obtained by MOLLI were comparable to the values obtained using the standard inversion recovery method. The hepatic T1 relaxation times measured by MOLLI technique with free-breathing were comparable to those obtained with breath-hold in children and young adults.

Indexed as

Breath HoldingRespirationAdolescentAdultChildContrast MediaFeasibility StudiesFemaleHumansLiverMagnetic Resonance ImagingMaleMeglumineOrganometallic CompoundsPhantoms, ImagingYoung AdultContrast Mediagadoterate meglumineMeglumineOrganometallic Compounds

Identifiers

PMID33110134
PMCPMC7591907
OpenAlexW3097516241

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.