Evidence mapPaperPMID 33149133Full record

ArticleScientific reports2020

Modelling and manufacturing of 3D-printed, patient-specific, and anthropomorphic gastric phantoms: a pilot study.

Jinhee Kwon, Joonmyeong Choi, Sangwook Lee, Minkyeong Kim, Yoon Kyung Park, Do Hyun Park, Namkug Kim

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Jinhee KwonDepartment of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea.
Joonmyeong ChoiDepartment of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea.
Sangwook LeeANYMEDI Inc, Seoul, 05505, South Korea.
Minkyeong KimDepartment of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea.
Yoon Kyung ParkGastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea.
Do Hyun ParkDepartment of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea. dhpark@amc.seoul.kr.
Namkug KimDepartment of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, South Korea. namkugkim@gmail.com.
Asan Medical Center · KRUlsan College · KRUniversity of Ulsan · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Interventional devices including intragastric balloons are widely used to treat obesity. This study aims to develop 3D-printed, patient-specific, and anthropomorphic gastric phantoms with mechanical properties similar to those of human stomach. Using computed tomography gastrography (CTG) images of three patients, gastric phantoms were modelled through shape registration to align the stomach shapes of three different phases. Shape accuracies of the original gastric models versus the 3D-printed phantoms were compared using landmark distances. The mechanical properties (elongation and tensile strength), number of silicone coatings (0, 2, and 8 times), and specimen hardness (50, 60, and 70 Shore A) of three materials (Agilus, Elastic, and Flexa) were evaluated. Registration accuracy was significantly lower between the arterial and portal phases (3.16 ± 0.80 mm) than that between the portal and delayed phases (8.92 ± 0.96 mm). The mean shape accuracy difference was less than 10 mm. The mean elongations and tensile strengths of the Agilus, Elastic, and Flexa were 264%, 145%, and 146% and 1.14, 1.59, and 2.15 MPa, respectively, and their mechanical properties differed significantly (all p < 0.05). Elongation and tensile strength assessments, CTG image registration and 3D printing resulted in highly realistic and patient-specific gastric phantoms with reasonable shape accuracies.

Indexed as

Phantoms, ImagingGastric BalloonHardnessHumansModels, BiologicalPilot ProjectsPrinting, Three-DimensionalRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesStomachTensile StrengthTomography, X-Ray Computed

Identifiers

PMID33149133
PMCPMC7643145
OpenAlexW3096928131

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.