Evidence map›Paper›PMID 33983883›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2021

Analysis of Negative Capacitance-Based Broadband Impedance Matching for CMUTs.

Ahmad Rezvanitabar, Evren F Arkan, F Levent Degertekin

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ahmad Rezvanitabar
Evren F Arkan
F Levent Degertekin

Funding

"Transcranial FUS therapy with closed-loop US image guidance and circulating tumor DNAR37CA239039 · NCI · GEORGIA INSTITUTE OF TECHNOLOGY · PI Konstantinos-Costas Arvanitis · 2020 to 2026
$3.3M
Feasibility of folded ultrasound arrays for high resolution 3-D imaging intracardiac echography cathetersR21EB024253 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI DEGERTEKIN, F. LEVENT · 2017 to 2018
$404k
TOWARDS A WIRELESS IMPLANTABLE INTRACRANIAL ULTRASOUND (WICUS) IMAGING SYSTEMR21NS108391 · NINDS · GEORGIA INSTITUTE OF TECHNOLOGY · PI DEGERTEKIN, F. LEVENT, GHOVANLOO, MAYSAM · 2018 to 2019
$402k
NCI NIH HHS R37 CA239039NIBIB NIH HHS R21 EB024253NINDS NIH HHS R21 NS108391
6 · The paper itself

Abstract

Tight integration of capacitive micromachined ultrasonic transducer (CMUT) arrays with integrated circuits can make active impedance matching feasible for practical imaging devices. In this article, negative capacitance-based impedance matching for CMUTs is investigated. Simple equivalent circuit model-based calculations show the potential of negative capacitance matching for improving the bandwidth along with electrical power transfer and acoustic reflectivity, but the model has limitations especially for acoustic reflectivity evaluation. For more realistic results, an experimentally validated CMUT array model is applied to a small 1-D CMUT array operating in the 5-15 MHz range. The results highlight the difference between electrical power transfer and acoustic reflectivity as well as the tradeoffs in signal-to-noise ratio (SNR). According to the results, ideal negative capacitance termination matched to the CMUT capacitance provides the broadest bandwidth and highest SNR if acoustic or electrical reflections are of no concern. On the other hand, negative capacitance and resistance matching to minimize acoustic reflectivity provides both lower reflection and closer to ideal SNR as compared with electrical power matching. It is observed that acoustic matching also reduces acoustic crosstalk and improves array uniformity. While several challenges for integrated circuit implementation are present, negative capacitance-based impedance matching can be a viable broadband active impedance matching method for CMUTs operating in conventional and collapsed mode as well as other ultrasound transducers with mainly capacitive impedance.

Indexed as

TransducersElectric ImpedanceEquipment DesignMiniaturizationUltrasonography

Identifiers

PMID33983883
PMCPMC8403164

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.