Evidence map›Paper›PMID 34006917›Full record

Observational studyScientific reports2021

Early bradycardia detection and therapeutic interventions in preterm infant monitoring.

Matthieu Doyen, Alfredo I Hernández, Cyril Flamant, Antoine Defontaine, Géraldine Favrais, Miguel Altuve, Bruno Laviolle, Alain Beuchée, Guy Carrault, Patrick Pladys

Open access · goldAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 2 countries.

Matthieu Doyen *Univ Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, 35000, Rennes, France.
Alfredo I Hernández *Univ Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, 35000, Rennes, France. alfredo.hernandez@inserm.fr.
Cyril FlamantUniv-Nantes, CHU Nantes, Inserm, CIC 0004, F-44000, Nantes, France.
Antoine DefontainePolyclinic Quimper, Dpt Thoracic Surgery, Campus de Beaulieu, Bat 22, F-29000, Quimper, France.
Géraldine FavraisUniv-Tours, CHU Tours, Inserm, Imagerie et Cerveau UMR930, F-37000, Tours, France.
Miguel AltuveFaculty of Electrical and Electronic Engineering, Pontifical Bolivarian University, Bucaramanga, Colombia.
Bruno LaviolleUniv-Rennes, CHU Rennes, Inserm, CIC 1414, F-35000, Rennes, France.
Alain BeuchéeUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, 35000, Rennes, France.
Guy CarraultUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, 35000, Rennes, France.
Patrick PladysUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, 35000, Rennes, France.
Laboratoire Traitement du Signal et de l'Image · FRHôpital Pontchaillou · FRInserm · FRCentre Hospitalier de Cornouaille · FRCIC Rennes · FRUniversidad Pontificia Bolivariana · CO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In very preterm infants, cardio-respiratory events and associated hypoxemia occurring during early postnatal life have been associated with risks of retinopathy, growth alteration and neurodevelopment impairment. These events are commonly detected by continuous cardio-respiratory monitoring in neonatal intensive care units (NICU), through the associated bradycardia. NICU nurse interventions are mainly triggered by these alarms. In this work, we acquired data from 52 preterm infants during NICU monitoring, in order to propose an early bradycardia detector which is based on a decentralized fusion of three detectors. The main objective is to improve automatic detection under real-life conditions without altering performance with respect to that of a monitor commonly used in NICU. We used heart rate lower than 80 bpm during at least 10 sec to define bradycardia. With this definition we observed a high rate of false alarms (64%) in real-life and that 29% of the relevant alarms were not followed by manual interventions. Concerning the proposed detection method, when compared to current monitors, it provided a significant decrease of the detection delay of 2.9 seconds, without alteration of the sensitivity (97.6% vs 95.2%) and false alarm rate (63.7% vs 64.1%). We expect that such an early detection will improve the response of the newborn to the intervention and allow for the development of new automatic therapeutic strategies which could complement manual intervention and decrease the sepsis risk.

Indexed as

BradycardiaHumansInfant, Extremely PrematureInfant, NewbornInfant, Premature, DiseasesIntensive Care Units, NeonatalMonitoring, Physiologic

Identifiers

PMID34006917
PMCPMC8131388
OpenAlexW3160663181

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked