Evidence map›Paper›PMID 34078949›Full record

ArticleScientific reports2021

Saphenous vein valve assessment utilizing upright CT to potentially improve graft assessment for bypass surgery.

Takehiro Nakahara, Minoru Yamada, Yoichi Yokoyama, Yoshitake Yamada, Keiichi Narita, Nobuaki Imanishi, Masataka Yamazaki, Hideyuki Shimizu, Jagat Narula, Masahiro Jinzaki

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Takehiro NakaharaDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan.
Minoru YamadaDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan.
Yoichi YokoyamaDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan.
Yoshitake YamadaDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan.
Keiichi NaritaDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan.
Nobuaki ImanishiDepartment of Plastic and Reconstructive Surgery, Keio University School of Medicine, Tokyo, Japan.
Masataka YamazakiDepartment of Cardiovascular Surgery, Keio University School of Medicine, Tokyo, Japan.
Hideyuki ShimizuDepartment of Cardiovascular Surgery, Keio University School of Medicine, Tokyo, Japan.
Jagat NarulaMount Sinai Heart, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Masahiro JinzakiDepartment of Radiology, Keio University School of Medicine, Shinanomachi 35, Shinjyuku, Tokyo, 160-8582, Japan. jinzaki@rad.med.keio.ac.jp.
Keio University · JPIcahn School of Medicine at Mount Sinai · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Saphenous veins (SVs) are frequently employed as bypass grafts. The SV graft failure is predominantly seen at the valve site. Avoiding valves during vein harvest would help reduce graft failure. We endeavored to detect SV valves, tributaries, and vessel size employing upright computed tomography (CT) for the raw cadaver venous samples and in healthy volunteers. Five cadaver legs were scanned. Anatomical analysis showed 3.0 (IQR: 2.0-3.0) valves and 13.50 (IQR: 10.00-16.25) tributaries. The upright CT completely detected, compared to 2.0 (IQR: 1.5-2.5, p = 0.06) valves and 9.5 (IQR: 7.5-13.0, p = 0.13) tributaries by supine CT. From a total of 190 volunteers, 138 (men:75, women:63) were included. The number of valves from the SF junction to 35 cm were significantly higher in upright CT than in supine CT bilaterally [upright vs. supine, Right: 4 (IQR: 3-5) vs. 2 (IQR:1-2), p < 0.0001, Left: 4 (IQR: 3-5) vs. 2 (IQR: 1-2), p < 0.0001]. The number of tributaries and vessel areas per leg were also higher for upright compared with supine CT. Upright CT enables non-invasive detection of SV valves, tributaries, and vessel size. Although not tested here, it is expected that upright CT may potentially improve graft assessment for bypass surgery.

Indexed as

Standing PositionAdultAgedAged, 80 and overCadaverFemaleHealthy VolunteersHumansLegMaleMiddle AgedSaphenous VeinSupine PositionTomography, X-Ray ComputedVascular GraftingVenous Valves

Identifiers

PMID34078949
PMCPMC8172633
OpenAlexW3165808423

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.