Evidence map›Paper›PMID 34410539›Full record

ArticleEJNMMI physics2021

Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study.

Michaella Morphis, Johan A van Staden, Hanlie du Raan, Michael Ljungberg

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. EANM guidance document: dosimetry for first-in-human studies and early phase clinical trials.European journal of nuclear medicine and molecular imaging · 2024
    Article
  4. Transarterial Radioembolization: Overview of Radioembolic Devices.Seminars in interventional radiology · 2023
    Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Michaella MorphisDepartment of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa. michaellamorphis@icloud.com.ORCID http://orcid.org/0000-0002-3100-1618
Johan A van StadenDepartment of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
Hanlie du RaanDepartment of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
Michael LjungbergMedical Radiation Physics, Lund University, Lund, Sweden.
University of the Free State · ZALund University · SE

Funding

NRF-STINT 160811184621South African Medical Research Council SAMRC-RFA-UFSP-01-2013/HARD
6 · The paper itself

Abstract

purposeThe quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well as image corrections incorporated in the iterative reconstruction process. These factors can be investigated and optimised using Monte Carlo simulations. This study aimed to evaluate SPECT quantification accuracy for

methodsSimulated SPECT projection images were reconstructed using the OS-EM iterative algorithm, which was optimised for the number of updates, with appropriate corrections for scatter, attenuation and collimator detector response (CDR), including septal scatter and penetration compensation. An appropriate calibration factor (CF) was determined from four different source geometries (activity-filled: water-filled cylindrical phantom, sphere in water-filled (cold) cylindrical phantom, sphere in air and point-like source), investigated with different volume of interest (VOI) diameters. Recovery curves were constructed from recovery coefficients to correct for partial volume effects (PVEs). The quantitative method was evaluated for spheres in voxel-based digital cylindrical and patient phantoms.

resultsThe optimal number of OS-EM updates was 60 for all isotope-collimator combinations. The CF

conclusionThe study showed that quantification errors of less than 6.0% could be attained, for all isotope-collimator combinations, if corrections for; scatter, attenuation, CDR (including septal scatter and penetration) and PVEs are performed.

Indexed as

123I131IMonte Carlo simulationsQuantification accuracySIMINDSPECT

Identifiers

PMID34410539
PMCPMC8377107
OpenAlexW3166636123

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390