ArticleMagnetic resonance imaging2021
Deep learning for radial SMS myocardial perfusion reconstruction using the 3D residual booster U-net.
Article in Magnetic resonance imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 23 citations in OpenAlex.
- Simultaneous Multi-Slice Acceleration for Free-Breathing Motion Corrected Late Gadolinium Enhancement Imaging.Magnetic resonance in medicine · 2026Article
- Application of deep learning for transformation of Chinese traditional cultural narrative patterns and enhancement of cultural identity empowered by AIGC.Scientific reports · 2025Article
- Artificial Intelligence-Based Arterial Input Function for the Quantitative Assessment of Myocardial Blood Flow and Perfusion Reserve in Cardiac Magnetic Resonance: A Validation Study.Diagnostics (Basel, Switzerland) · 2025Article
- Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.Journal of magnetic resonance imaging : JMRI · 2025Article
- Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025Article
- A review of deep learning-based reconstruction methods for accelerated MRI using spatiotemporal and multi-contrast redundancies.Biomedical engineering letters · 2024Review
- High-angular resolution diffusion imaging generation using 3d u-net.Neuroradiology · 2024Article
- Fast reconstruction of SMS bSSFP myocardial perfusion images using noise map estimation network (NoiseMapNet): a head-to-head comparison with parallel imaging and iterative reconstruction.Frontiers in cardiovascular medicine · 2024Article
- Present and Future Innovations in AI and Cardiac MRI.Radiology · 2024Review
- Signal intensity informed multi-coil encoding operator for physics-guided deep learning reconstruction of highly accelerated myocardial perfusion CMR.Magnetic resonance in medicine · 2023Article
- ReCSAI: recursive compressed sensing artificial intelligence for confocal lifetime localization microscopy.BMC bioinformatics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo develop an end-to-end deep learning solution for quickly reconstructing radial simultaneous multi-slice (SMS) myocardial perfusion datasets with comparable quality to the pixel tracking spatiotemporal constrained reconstruction (PT-STCR) method.
methodsDynamic contrast enhanced (DCE) radial SMS myocardial perfusion data were obtained from 20 subjects who were scanned at rest and/or stress with or without ECG gating using a saturation recovery radial CAIPI turboFLASH sequence. Input to the networks consisted of complex coil combined images reconstructed using the inverse Fourier transform of undersampled radial SMS k-space data. Ground truth images were reconstructed using the PT-STCR pipeline. The performance of the residual booster 3D U-Net was tested by comparing it to state-of-the-art network architectures including MoDL, CRNN-MRI, and other U-Net variants.
resultsResults demonstrate significant improvements in speed requiring approximately 8 seconds to reconstruct one radial SMS dataset which is approximately 200 times faster than the PT-STCR method. Images reconstructed with the residual booster 3D U-Net retain quality of ground truth PT-STCR images (0.963 SSIM/40.238 PSNR/0.147 NRMSE). The residual booster 3D U-Net has superior performance compared to existing network architectures in terms of image quality, temporal dynamics, and reconstruction time.
conclusionResidual and booster learning combined with the 3D U-Net architecture was shown to be an effective network for reconstructing high-quality images from undersampled radial SMS datasets while bypassing the reconstruction time of the PT-STCR method.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.