Evidence map›Paper›PMID 34559244›Full record

ArticleNeuroradiology2022

Usefulness of rapid MR angiography using two-point Dixon for evaluating carotid and aortic plaques.

Keisuke Morihara, Tatsu Nakano, Kentaro Mori, Issei Fukui, Motohiro Nomura, Keiichiro Suzuki, Kenichi Hirano, Mitsuyuki Takahashi, Hideyuki Takeuchi, Hiroshi Doi and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Keisuke Morihara *Department of Neurology, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Tatsu Nakano *Department of Neurology, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Kentaro MoriDepartment of Neurosurgery, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Issei FukuiDepartment of Neurosurgery, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Motohiro NomuraDepartment of Neurosurgery, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Keiichiro SuzukiDepartment of Radiology, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Kenichi HiranoDepartment of Radiology, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Mitsuyuki TakahashiDepartment of Radiology, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Hideyuki TakeuchiDepartment of Neurology and Stroke Medicine, Yokohama City University Graduate School of Medicine, Yokohama, Japan.
Hiroshi DoiDepartment of Neurology and Stroke Medicine, Yokohama City University Graduate School of Medicine, Yokohama, Japan.
Yoshihisa KitamuraDepartment of Neurosurgery, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Fumiaki TanakaDepartment of Neurology and Stroke Medicine, Yokohama City University Graduate School of Medicine, Yokohama, Japan. ftanaka@yokohama-cu.ac.jp.ORCID http://orcid.org/0000-0002-9961-2693
Yokohama Sakae Kyosai Hospital · JPYokohama City University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRecently, various magnetic resonance imaging (MRI) modalities have been developed to easily detect carotid and aortic plaques, but these techniques are time-consuming and vulnerable to motion artifacts. We investigated the utility of a gradient echo MRI technique known as liver acquisition with volume acceleration flexible (LAVA-Flex) to detect carotid and aortic atherosclerotic plaques.

methodsTen patients who underwent carotid endarterectomy (CEA) were assessed regarding the correspondence between LAVA-Flex findings and the histopathology of excised carotid plaques. In addition, 47 patients with cryptogenic ischemic stroke underwent LAVA-Flex and transesophageal echocardiography (TEE) for detection of embolic sources in the thoracic aorta. We analyzed the relationship between the thickness of the aortic plaque measured by TEE and the presence of high-intensity lesions on LAVA-Flex.

resultsNine of 10 patients (90.0%) who underwent CEA showed a high-intensity carotid lesion on LAVA-Flex, which corresponded pathologically to plaques containing large lipid cores and hemorrhage. Twenty-four (51.1%) of 47 cryptogenic stroke patients showed a high-intensity lesion in the thoracic aorta on LAVA-Flex; of these, 21 (87.5%) also demonstrated a large plaque (thickness ≥4 mm) on TEE. Twenty-two (95.7%) of 23 patients without a high-intensity lesion on LAVA-Flex demonstrated no large plaque on TEE. LAVA-Flex had a sensitivity of 95.5% and a specificity of 88.0% in patients with large plaques.

conclusionThis study showed that LAVA-Flex successfully detected carotid and aortic plaques. This imaging technique may be useful to rapidly diagnose and evaluate carotid and aortic plaques, which are critical risk factors for aortogenic stroke.

Indexed as

Plaque, AtheroscleroticStrokeAngiographyCarotid ArteriesHumansMagnetic Resonance ImagingAortic plaqueIntraplaque hemorrhageLAVA-FlexTransesophageal echocardiography

Identifiers

PMID34559244
OpenAlexW3200761559

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.