Evidence map›Paper›PMID 34863194›Full record

ArticleBiomedical engineering online2021

Camera-based heart rate estimation for hospitalized newborns in the presence of motion artifacts.

Qiong Chen, Yalin Wang, Xiangyu Liu, Xi Long, Bin Yin, Chen Chen, Wei Chen

Abstract read
In one paragraph

Article in Biomedical engineering online, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qiong ChenCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China.
Yalin WangCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China.
Xiangyu LiuSchool of Art Design and Media, East China University of Science and Technology, Shanghai, China.
Xi LongDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands. x.long@tue.nl.
Bin YinConnected Care and Personal Health Department, Philips Research, Shanghai, China.
Chen ChenHuman Phenome Institute, Fudan University, Shanghai, China. chenchen_fd@fudan.edu.cn.
Wei ChenCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China. w_chen@fudan.edu.cn.

Funding

national key r&d program of china 2017YFE0112000shanghai municipal science and technology major project 2017SHZDZX01
6 · The paper itself

Abstract

backgroundHeart rate (HR) is an important vital sign for evaluating the physiological condition of a newborn infant. Recently, for measuring HR, novel RGB camera-based non-contact techniques have demonstrated their specific superiority compared with other techniques, such as dopplers and thermal cameras. However, they still suffered poor robustness in infants' HR measurements due to frequent body movement.

methodsThis paper introduces a framework to improve the robustness of infants' HR measurements by solving motion artifact problems. Our solution is based on the following steps: morphology-based filtering, region-of-interest (ROI) dividing, Eulerian video magnification and majority voting. In particular, ROI dividing improves ROI information utilization. The majority voting scheme improves the statistical robustness by choosing the HR with the highest probability. Additionally, we determined the dividing parameter that leads to the most accurate HR measurements. In order to examine the performance of the proposed method, we collected 4 hours of videos and recorded the corresponding electrocardiogram (ECG) of 9 hospitalized neonates under two different conditions-rest still and visible movements.

resultsExperimental results indicate a promising performance: the mean absolute error during rest still and visible movements are 3.39 beats per minute (BPM) and 4.34 BPM, respectively, which improves at least 2.00 and 1.88 BPM compared with previous works. The Bland-Altman plots also show the remarkable consistency of our results and the HR derived from the ground-truth ECG.

conclusionsTo the best of our knowledge, this is the first study aimed at improving the robustness of neonatal HR measurement under motion artifacts using an RGB camera. The preliminary results have shown the promising prospects of the proposed method, which hopefully reduce neonatal mortality in hospitals.

Indexed as

ArtifactsPhotoplethysmographyElectrocardiographyHeart RateHumansInfantInfant, NewbornMotionBiomedical signal processingEulerian video magnificationHeart rateMotion artifactsRemote photoplethysmography (rPPG)

Identifiers

PMID34863194
PMCPMC8642856

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.