Evidence map›Paper›PMID 34943625›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Plethysmography System to Monitor the Jugular Venous Pulse: A Feasibility Study.

Antonino Proto, Daniele Conti, Erica Menegatti, Angelo Taibi, Giacomo Gadda

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Antonino ProtoDepartment of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 70800 Ostrava, Czech Republic.ORCID 0000-0003-1964-8184
Daniele ContiDepartment of Physics and Earth Sciences, University of Ferrara, Via Saragat 1, 44122 Ferrara, Italy.ORCID 0000-0001-7790-1921
Erica MenegattiVascular Diseases Center, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 4, 44124 Ferrara, Italy.ORCID 0000-0003-0850-1654
Angelo TaibiDepartment of Physics and Earth Sciences, University of Ferrara, Via Saragat 1, 44122 Ferrara, Italy.ORCID 0000-0002-2494-8993
Giacomo GaddaSection of Ferrara, National Institute for Nuclear Physics (INFN), Via Saragat 1, 44122 Ferrara, Italy.
Istituto Nazionale di Fisica Nucleare · ITUniversity of Ferrara · ITVSB - Technical University of Ostrava · CZ

Funding

Biomedical Engineering Systems XVII SV4500X21.2101, SP2021/112INFN, WISE Project grant for Young Researchers 2018
6 · The paper itself

Abstract

Cerebral venous outflow is investigated in the diagnosis of heart failure through the monitoring of jugular venous pulse, an indicator to assess cardiovascular diseases. The jugular venous pulse is a weak signal stemming from the lying internal jugular vein and often invasive methodologies requiring surgery are mandatory to detect it. Jugular venous pulse can also be extrapolated via the ultrasound technique, but it requires a qualified healthcare operator to perform the examination. In this work, a wireless, user-friendly, wearable device for plethysmography is developed to investigate the possibility of monitoring the jugular venous pulse non-invasively. The proposed device can monitor the jugular venous pulse and the electrocardiogram synchronously. To study the feasibility of using the proposed device to detect physiological variables, several measurements were carried out on healthy subjects by considering three different postures: supine, sitting, and upright. Data acquired in the experiment were properly filtered to highlight the cardiac oscillation and remove the breathing contribution, which causes a considerable shift in the amplitude of signals. To evaluate the proper functioning of the wearable device for plethysmography, a comparison with the ultrasound technique was carried out. As a satisfactory result, the acquired signals resemble the typical jugular venous pulse waveforms found in literature.

Indexed as

capacitive strain gaugeelectrocardiographyinternal jugular veinjugular venous pulseplethysmographywearable device

Identifiers

PMID34943625
PMCPMC8699927
OpenAlexW4200099494

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.