Evidence map›Paper›PMID 35083124›Full record

ArticleJournal of the Saudi Heart Association2021

Study of Safety and Efficacy of Novel Sirolimus-Eluting Stent Incorporating Properties of Drug Coating Balloon Among Real World Patients Focusing Younger Population (<35 years).

Santosh Kumar Sinha, Umeshwar Pandey, Mahmodullah Razi, Awadesh Kumar Sharma, Puneet Aggarwal, Mohit Sachan, Praveen Shukla, Ramesh Thakur

Open access · diamondAbstract read
In one paragraph

Article in Journal of the Saudi Heart Association, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Santosh Kumar SinhaDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Umeshwar PandeyDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Mahmodullah RaziDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Awadesh Kumar SharmaDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Puneet AggarwalDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Mohit SachanDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Praveen ShuklaDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Ramesh ThakurDepartment of Cardiology, LPS Institute of Cardiology, Kanpur, India.
Ganesh Shankar Vidyarthi Memorial Medical College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAim of study was to evaluate safety and efficacy of abluminal Mitigator DES + Sirolimus Eluting Stent (Envision Scientific, Surat, India) incorporating novel technology of fusion coating of bioresorbable polymer on both abluminal surface of stent and exposed parts of balloon among real world patients specially focusing younger patients (<35 years).

method1293 patients received Mitigator DES + at LPS Institute of Cardiology, Kanpur, India. Primary outcome was target lesion failure (TLF)- composite of cardiovascular death, target vessel myocardial infarction (TVMI), and target lesion revascularization (TLR) and secondary end points including peri-procedural device failure (failure of stent delivery, change of stent, stent fracture), target vessel failure (TVF), and patient oriented composite end point (POCE)-composite of all deaths, MI, and revascularization and stent thrombosis (ST) at 1-year follow-up.

resultYounger population comprised of 374 (29%) patients. Various indications of interventions were STEMI (n = 614; 47.4%), NSTEMI (n = 416; 32.2%), UA (n = 161; 12.5%), and CCS (n = 102; 7.9%). TLF at 1 year in young and overall population were 3.4% and 3.5% respectively which was driven by TVMI and TLR in 1.3% and 1.1% patients respectively. POCE was observed in 9.5% in each group mainly contributed by any revascularization (3.9%). Device failure was significantly lower in young group than overall population (1.3% vs. 2.2%; p = 0.04) which was mainly driven by stent delivery (1.1%) and edge dissection (0.5%). Definite and probable ST was 1.3% and 1.7% respectively which was not significant. Young patients showed insignificantly lower TLF, TVF, ST and POCE and significantly lower device failure (1.3% vs. 2.6%; p = 0.04) when compared to patients >35 years. On multivariate regression analysis, complex lesion, in-stent restenosis, failure of stent delivery and edge dissection were independent predictors of events or device success rate.

conclusionMitigator DES+™ is safe among real world patients, including young population.

Indexed as

Drug-eluting stentPatient oriented composite end pointPercutaneous coronary interventionStent thrombosisTarget lesion failure

Identifiers

PMID35083124
PMCPMC8754438
OpenAlexW3214423409

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.