Evidence map›Paper›PMID 35148759›Full record

ArticleBiomedical engineering online2022

Stochastic integrated model-based protocol for volume-controlled ventilation setting.

Jay Wing Wai Lee, Yeong Shiong Chiew, Xin Wang, Mohd Basri Mat Nor, J Geoffrey Chase, Thomas Desaive

Abstract read
In one paragraph

Article in Biomedical engineering online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jay Wing Wai LeeSchool of Engineering, Monash University Malaysia, Subang Jaya, Selangor, Malaysia.
Yeong Shiong ChiewSchool of Engineering, Monash University Malaysia, Subang Jaya, Selangor, Malaysia. chiew.yeong.shiong@monash.edu.
Xin WangSchool of Engineering, Monash University Malaysia, Subang Jaya, Selangor, Malaysia.
Mohd Basri Mat NorKulliyah of Medicine, International Islamic University Malaysia, Kuantan, Malaysia.
J Geoffrey ChaseCenter of Bioengineering, University of Canterbury, Christchurch, New Zealand.
Thomas DesaiveGIGA In-Silico Medicine, University of Liege, Liege, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectiveMechanical ventilation (MV) is the primary form of care for respiratory failure patients. MV settings are based on general clinical guidelines, intuition, and experience. This approach is not patient-specific and patients may thus experience suboptimal, potentially harmful MV care. This study presents the Stochastic integrated VENT (SiVENT) protocol which combines model-based approaches of the VENT protocol from previous works, with stochastic modelling to take the variation of patient respiratory elastance over time into consideration.

methodsA stochastic model of E

resultsFrom an initial number of 189,000 possible MV setting combinations, the VENT protocol reduced this number to a median of 10,612, achieving a reduction of 94.4% across the cohort. With the integration of the stochastic model component, the SiVENT protocol reduced this number from 189,000 to a median of 9329, achieving a reduction of 95.1% across the cohort. The SiVENT protocol reduces the number of possible combinations provided to the user by more than 1000 combinations as compared to the VENT protocol.

conclusionsAdding a stochastic model component into a model-based approach to selecting MV settings improves the ability of a decision support system to recommend patient-specific MV settings. It specifically considers inter- and intra-patient variability in respiratory elastance and eliminates potentially harmful settings based on clinically recommended pressure thresholds. Clinical input and local protocols can further reduce the number of safe setting combinations. The results for the SiVENT protocol justify further investigation of its prediction accuracy and clinical validation trials.

Indexed as

Respiration, ArtificialRespiratory SystemHumansRetrospective StudiesCritical careDecision-makingMechanical ventilationModel-based protocolRespiratory mechanicsStochastic modelling

Identifiers

PMID35148759
PMCPMC8832735

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.