Evidence map›Paper›PMID 35282068›Full record

ArticleAnnals of translational medicine2022

Development and validation of an UHPLC-Orbitrap-HRMS method for rapid determination of endogenous L-carnitine in patients on hemodialysis/peritoneal dialysis and its application to promote rational drug use.

Wen-Ting Jiang, Liu-Xing Tang, Jie Pan, Cun-Jin Su, Zhu Shen, Zhan-Hong Hu, Zhou-Bing Zhan, Ai-Ming Shi

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Wen-Ting Jiang *Department of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Liu-Xing Tang *Department of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Jie PanDepartment of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Cun-Jin SuDepartment of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Zhu ShenDepartment of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Zhan-Hong HuDepartment of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Zhou-Bing ZhanDepartment of Nephrology, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Ai-Ming ShiDepartment of Pharmacy, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Second Affiliated Hospital of Soochow University · CNSoochow University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: L-carnitine is an endogenous vitamin-like amino acid derivate which plays an essential role in energy metabolism and can be easily lost via dialysis. Deficiency of L-carnitine has great effects on many aspects of bodily functions. To determine the deficiency degree and adjust the supplementation dose, a rapid, sensitive, and specific method for the detection of endogenous L-carnitine in the plasma of dialysis patients using ultra-high performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) was developed and validated. Methods: The plasma samples were processed by protein precipitation and centrifugation before analysis using UHPLC-Orbitrap-HRMS. Sample separation was achieved with a hydrophilic interaction liquid chromatography (HILIC) column, using an isocratic elution with a runtime of 5 min. The separated analytes were detected by positive ionization mode in full scan mode and targeted-single ion monitoring (t-SIM) mode. Mildronate was used as the internal standard (IS). Results: All the plasma could be detected in the range of 6.169 to 197.394 µM, with adequate accuracy, precision, and recovery. The method was validated in fortified validation with relative standard deviations (RSD) 5.15-8.74%. This method was applied to the analysis of 105 dialysis patients and 39 healthy participants, the results revealed that peritoneal dialysis patients without L-carnitine supplementation should pay more attention to L-carnitine monitoring, meanwhile, all the hemodialysis patients were advised to be routinely given a full dose of L-carnitine, no matter whether they had taken L-carnitine or not. Conclusions: This study developed a simple and rapid UHPLC-Orbitrap-HRMS method for detection of endogenous L-carnitine in dialysis patients, which could be useful to promote rational drug use.

Indexed as

dialysisfortified validationL-carnitinerational drug useUHPLC-Orbitrap-HRMS

Identifiers

PMID35282068
PMCPMC8848361
OpenAlexW4210405073

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.