Evidence map›Paper›PMID 35466707›Full record

Trial reportJournal of diabetes science and technology2023

Accuracy of a Seventh-Generation Continuous Glucose Monitoring System in Children and Adolescents With Type 1 Diabetes.

Lori M Laffel, Timothy S Bailey, Mark P Christiansen, Jennifer L Reid, Stayce E Beck

Registry-linked trialOpen access · bronzeAbstract readClinical Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04794478 (Evaluation of the Safety and Effectiveness of the Dexcom Continuous Glucose Monitoring), which is not on this map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04794478 nacompletednot on this map

Evaluation of the Safety and Effectiveness of the Dexcom Continuous Glucose Monitoring (CGM) System

TypeinterventionalSponsorDexCom, Inc.Ran2021 to 2021Enrolled482ConditionsDiabetes MellitusArmsDexcom Continuous Glucose Monitoring System
3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Review
  16. Review
  17. Review
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Lori M LaffelJoslin Diabetes Center, Harvard Medical School, Boston, MA, USA.ORCID 0000-0002-9675-3001
Timothy S BaileyAMCR Institute, Escondido, CA, USA.ORCID 0000-0003-4178-3462
Mark P ChristiansenDiablo Clinical Research, Walnut Creek, CA, USA.
Jennifer L ReidDexcom, Inc., San Diego, CA, USA.
Stayce E BeckDexcom, Inc., San Diego, CA, USA.
Dexcom (United States) · USAMCR Institute · USDiablo Clinical Research · USJoslin Diabetes Center · US

Funding

SPECIAL ASSAY COREP30DK036836 · NIDDK · JOSLIN DIABETES CENTER · PI ROHIT N. KULKARNI · 1986 to 2026
$50.5M
NIDDK NIH HHS P30 DK036836
6 · The paper itself

Abstract

backgroundAccuracy of a seventh-generation "G7" continuous glucose monitoring (CGM) system was evaluated in children and adolescents with type 1 diabetes (T1D).

methodsSensors were worn on the upper arm and abdomen. The CGM data were available from 127 of 132 participants, ages 7 to 17 years, across 10.5 days of use, various glucose concentration ranges, and various rates of glucose change for comparisons with temporally matched venous blood glucose measurements (YSI). Data were also available from 28 of 32 participants, ages 2 to 6 years, for whom capillary (fingerstick) blood provided comparator glucose values. Accuracy metrics included the mean absolute relative difference (MARD) between CGM and comparator glucose pairs, the proportion of CGM values within 15 mg/dL or 15% of comparator values <100 or ≥100 mg/dL, respectively, and the analogous %20/20 and %30/30 agreement rates.

resultsFor participants aged 7 to 17, a total of 15 437 matched pairs were obtained from 122 arm-placed and 118 abdomen-placed sensors. For arm-placed sensors, the overall MARD was 8.1% and overall %15/15, %20/20, and %30/30 agreement rates were 88.8%, 95.3%, and 98.7%, respectively. For abdomen-placed sensors, the overall MARD was 9.0% and overall %15/15, %20/20, and %30/30 agreement rates were 86.0%, 92.9%, and 97.7%, respectively. Good accuracy was maintained across wear days, glucose ranges, and rates of glucose change. Among those aged 2 to 6, a total of 343 matched pairs provided an overall MARD of 9.3% and an overall %20/20 agreement rate of 91.5%.

conclusionsThe G7 CGM placed on the arm or abdomen was accurate in children and adolescents with T1D. NCT#: NCT04794478.

Indexed as

Diabetes Mellitus, Type 1AbdomenAdolescentBlood GlucoseBlood Glucose Self-MonitoringChildHumansReproducibility of ResultsBlood Glucoseaccuracycontinuous glucose monitoringDexcomG7MARDpediatrics

Identifiers

PMID35466707
PMCPMC10347986
OpenAlexW4224694771

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.