Trial reportJournal of diabetes science and technology2023
Accuracy of a Seventh-Generation Continuous Glucose Monitoring System in Children and Adolescents With Type 1 Diabetes.
Trial report in Journal of diabetes science and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04794478 (Evaluation of the Safety and Effectiveness of the Dexcom Continuous Glucose Monitoring), which is not on this map. Cited by 24 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation of the Safety and Effectiveness of the Dexcom Continuous Glucose Monitoring (CGM) System
Who cites it
24 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.
- International Society for Pediatric and Adolescent Diabetes Clinical Practice Consensus Guidelines 2024 Diabetes Technologies: Glucose Monitoring.Hormone research in paediatrics · 2024Guideline
- Pediatric Inpatient Continuous Glucose Monitor Accuracy by Sensor Wear Day, Hospital Day, and Glucose Rate of Change.Diabetes technology & therapeutics · 2026Article
- CGM Accuracy in a Fragmented Regulatory Landscape: A Commentary on Harmonisation and Recent Evidence.Diabetes, obesity & metabolism · 2026Article
- Clinical accuracy of Dexcom G6 and G7 continuous glucose monitors in hospitalized pediatric patients with type 1 diabetes: a real-world study.Annals of pediatric endocrinology & metabolism · 2026Article
- Performance, Safety and Usability of a Third-Generation Continuous Glucose Monitoring System in a Pediatric Population: Results From a Prospective, Multicenter Study.Journal of diabetes science and technology · 2026Article
- Reduced Diabetes Burden Over Glycemic Gains With the Dexcom G7 Upgrade in Youth on Automated Insulin Delivery System.Diabetes, obesity & metabolism · 2026Article
- International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring.Diabetes, obesity & metabolism · 2026Review
- Pre-Type 1 Diabetes in Adolescents and Teens: Screening, Nutritional Interventions, Beta-Cell Preservation, and Psychosocial Impacts.Journal of clinical medicine · 2025Review
- Towards Standardization of CGM Performance Studies: The QUSS-CGM Questionnaire for Assessing User Satisfaction.Patient related outcome measures · 2025Article
- Continuous Glucose Monitoring-New Diagnostic Tool in Complex Pathophysiological Disorder of Glucose Metabolism in Children and Adolescents with Obesity.Diagnostics (Basel, Switzerland) · 2024Review
- Consensus Considerations and Good Practice Points for Use of Continuous Glucose Monitoring Systems in Hospital Settings.Diabetes care · 2024Review
- The Importance of Trial Design in Evaluating the Performance of Continuous Glucose Monitoring Systems: Details Matter.Journal of diabetes science and technology · 2024Article
- Evidence from clinical trials on high-risk medical devices in children: a scoping review.Pediatric research · 2024Article
- Perceptions of Continuous Glucose Monitoring Systems in the T1D Exchange Diabetes Registry: Satisfaction, Concerns, and Areas for Future Improvement.Clinical diabetes : a publication of the American Diabetes Association · 2024Article
- Evaluating the precision and reliability of real-time continuous glucose monitoring systems in ambulatory settings: a systematic review.Therapeutic advances in endocrinology and metabolism · 2024Review
- Comparisons of Fifth-, Sixth-, and Seventh-Generation Continuous Glucose Monitoring Systems.Journal of diabetes science and technology · 2024Review
- 7. Diabetes Technology: Standards of Care in Diabetes-2024.Diabetes care · 2024Review
- Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.Journal of diabetes science and technology · 2023Article
- Flash Glucose Monitoring in Croatia: The Optimal Number of Scans per Day to Achieve Good Glycemic Control in Type 1 Diabetes.Medicina (Kaunas, Lithuania) · 2023Article
- Narrative review of the role of technology in pediatric diabetes: from testing blood glucose to subcutaneous automated therapy and hope for cure.Translational pediatrics · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
Abstract
backgroundAccuracy of a seventh-generation "G7" continuous glucose monitoring (CGM) system was evaluated in children and adolescents with type 1 diabetes (T1D).
methodsSensors were worn on the upper arm and abdomen. The CGM data were available from 127 of 132 participants, ages 7 to 17 years, across 10.5 days of use, various glucose concentration ranges, and various rates of glucose change for comparisons with temporally matched venous blood glucose measurements (YSI). Data were also available from 28 of 32 participants, ages 2 to 6 years, for whom capillary (fingerstick) blood provided comparator glucose values. Accuracy metrics included the mean absolute relative difference (MARD) between CGM and comparator glucose pairs, the proportion of CGM values within 15 mg/dL or 15% of comparator values <100 or ≥100 mg/dL, respectively, and the analogous %20/20 and %30/30 agreement rates.
resultsFor participants aged 7 to 17, a total of 15 437 matched pairs were obtained from 122 arm-placed and 118 abdomen-placed sensors. For arm-placed sensors, the overall MARD was 8.1% and overall %15/15, %20/20, and %30/30 agreement rates were 88.8%, 95.3%, and 98.7%, respectively. For abdomen-placed sensors, the overall MARD was 9.0% and overall %15/15, %20/20, and %30/30 agreement rates were 86.0%, 92.9%, and 97.7%, respectively. Good accuracy was maintained across wear days, glucose ranges, and rates of glucose change. Among those aged 2 to 6, a total of 343 matched pairs provided an overall MARD of 9.3% and an overall %20/20 agreement rate of 91.5%.
conclusionsThe G7 CGM placed on the arm or abdomen was accurate in children and adolescents with T1D. NCT#: NCT04794478.
Indexed as
Identifiers
What Socratic holds
Registered trials