Evidence map›Paper›PMID 35715135›Full record

ArticleAnalytica chimica acta2022

Electromagnetically-driven integrated microfluidic platform using reverse transcription loop-mediated isothermal amplification for detection of severe acute respiratory syndrome coronavirus 2.

Yu-Shiuan Tsai, Chih-Hung Wang, Huey-Pin Tsai, Yan-Shen Shan, Gwo-Bin Lee

Abstract read
In one paragraph

Article in Analytica chimica acta, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yu-Shiuan TsaiDepartment of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan.
Chih-Hung WangDepartment of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan.
Huey-Pin TsaiDepartment of Pathology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Medical Laboratory Science and Biotechnology, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
Yan-Shen ShanInstitute of Clinical Medicine, National Cheng Kung University Hospital, National Cheng Kung University, Tainan, Taiwan; Division of General Surgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
Gwo-Bin LeeDepartment of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan; Institute of NanoEngineering and Microsystems, National Tsing Hua University, Hsinchu, Taiwan. Electronic address: gwobin@pme.nthu.edu.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rapid, sensitive and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is of great need for effective quarantining and treatment. Real-time reverse-transcription polymerase chain reaction requiring thermocyling has been commonly used for diagnosis of SARS-CoV-2 though it may take two to 4 h before lengthy sample pretreatment process and require bulky apparatus and well-trained personnel. Since multiple reverse transcription loop-mediated isothermal amplification (multiple RT-LAMP) process without thermocycling is sensitive, specific and fast, an electromagnetically-driven microfluidic chip (EMC) was developed herein to lyse SARS-CoV-2 viruses, extract their RNAs, and perform qualitative analysis of three marker genes by on-chip multiple RT-LAMP in an automatic format within 82 min at a limit of detection of only ∼5000 copies per reaction (i.e. 200 virus/ μL). This compact EMC may be especially promising for SARS-CoV-2 diagnostics in resource-limited countries.

Indexed as

COVID-19SARS-CoV-2Clinical Laboratory TechniquesCOVID-19 TestingHumansMicrofluidicsMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesReverse TranscriptionRNA, ViralSensitivity and SpecificityRNA, ViralCOVID-19MicrofluidicsMicromixersMicropumpsMultiple RT-LAMPPoint-of-care

Identifiers

PMID35715135
PMCPMC9167649

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.