Evidence map›Paper›PMID 35800676›Full record

ArticleComputational intelligence and neuroscience2022

Analysis of Vessel Segmentation Based on Various Enhancement Techniques for Improvement of Vessel Intensity Profile.

Sonali Dash, Sahil Verma, Kavita, SeongKi Kim, Jana Shafi, Muhammad Fazal Ijaz

Abstract read
In one paragraph

Article in Computational intelligence and neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sonali DashDepartment of Computer Science and Engineering, Chandigarh University, Mohali 140413, India.ORCID https://orcid.org/0000-0002-6153-2655
Sahil VermaDepartment of Computer Science and Engineering, Chandigarh University, Mohali 140413, India.ORCID https://orcid.org/0000-0003-3136-4029
KavitaDepartment of Computer Science and Engineering, Chandigarh University, Mohali 140413, India.ORCID https://orcid.org/0000-0001-5422-1659
SeongKi KimNational Centre of Excellence in Software, Sangmyung University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-2664-3632
Jana ShafiDepartment of Computer Science, College of Arts and Science, Prince Sattam bin Abdul Aziz University, Wadi Ad-Dawasir 11991, Saudi Arabia.ORCID https://orcid.org/0000-0001-6859-670X
Muhammad Fazal IjazDepartment of Intelligent Mechatronics Engineering, Sejong University, Seoul 05006, Republic of Korea.ORCID https://orcid.org/0000-0001-5206-272X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is vital to develop an appropriate prediction model and link carefully to measurable events such as clinical parameters and patient outcomes to analyze the severity of the disease. Timely identifying retinal diseases is becoming more vital to prevent blindness among young and adults. Investigation of blood vessels delivers preliminary information on the existence and treatment of glaucoma, retinopathy, and so on. During the analysis of diabetic retinopathy, one of the essential steps is to extract the retinal blood vessel accurately. This study presents an improved Gabor filter through various enhancement approaches. The degraded images with the enhancement of certain features can simplify image interpretation both for a human observer and for machine recognition. Thus, in this work, few enhancement approaches such as Gamma corrected adaptively with distributed weight (GCADW), joint equalization of histogram (JEH), homomorphic filter, unsharp masking filter, adaptive unsharp masking filter, and particle swarm optimization (PSO) based unsharp masking filter are taken into consideration. In this paper, an effort has been made to improve the performance of the Gabor filter by combining it with different enhancement methods and to enhance the detection of blood vessels. The performance of all the suggested approaches is assessed on publicly available databases such as DRIVE and CHASE_DB1. The results of all the integrated enhanced techniques are analyzed, discussed, and compared. The best result is delivered by PSO unsharp masking filter combined with the Gabor filter with an accuracy of 0.9593 for the DRIVE database and 0.9685 for the CHASE_DB1 database. The results illustrate the robustness of the recommended model in automatic blood vessel segmentation that makes it possible to be a clinical support decision tool in diabetic retinopathy diagnosis.

Indexed as

Diabetic RetinopathyAlgorithmsDatabases, FactualHumansImage EnhancementImage Processing, Computer-AssistedRetinal Vessels

Identifiers

PMID35800676
PMCPMC9256369

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.