Evidence map›Paper›PMID 35894013›Full record

ArticleTomography (Ann Arbor, Mich.)2022

Reduction in Acquisition Time and Improvement in Image Quality in T2-Weighted MR Imaging of Musculoskeletal Tumors of the Extremities Using a Novel Deep Learning-Based Reconstruction Technique in a Turbo Spin Echo (TSE) Sequence.

Daniel Wessling, Judith Herrmann, Saif Afat, Dominik Nickel, Ahmed E Othman, Haidara Almansour, Sebastian Gassenmaier

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Daniel WesslingDepartment of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.
Judith HerrmannDepartment of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.ORCID 0000-0003-1535-8980
Saif AfatDepartment of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.ORCID 0000-0002-6861-6245
Dominik NickelMR Application Predevelopment, Siemens Healthcare GmbH, 91052 Erlangen, Germany.
Ahmed E OthmanDepartment of Diagnostic and Interventional Neuroradiology, University Hospital of Mainz, 55131 Mainz, Germany.
Haidara AlmansourDepartment of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.
Sebastian GassenmaierDepartment of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany.ORCID 0000-0003-3701-2227
University of Tübingen · DEJohannes Gutenberg University Mainz · DESiemens Healthineers (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The aim of this study was to assess the technical feasibility and the impact on image quality and acquisition time of a deep learning-accelerated fat-saturated T2-weighted turbo spin echo sequence in musculoskeletal imaging of the extremities. Methods: Twenty-three patients who underwent MRI of the extremities were prospectively included. Standard T2w turbo inversion recovery magnitude (TIRMStd) imaging was compared to a deep learning-accelerated T2w TSE (TSEDL) sequence. Image analysis of 23 patients with a mean age of 60 years (range 30−86) was performed regarding image quality, noise, sharpness, contrast, artifacts, lesion detectability and diagnostic confidence. Pathological findings were documented measuring the maximum diameter. Results: The analysis showed a significant improvement for the T2 TSEDL with regard to image quality, noise, contrast, sharpness, lesion detectability, and diagnostic confidence, as compared to T2 TIRMStd (each p < 0.001). There were no differences in the number of detected lesions. The time of acquisition (TA) could be reduced by 52−59%. Interrater agreement was almost perfect (κ = 0.886). Conclusion: Accelerated T2 TSEDL was technically feasible and superior to conventionally applied T2 TIRMStd. Concurrently, TA could be reduced by 52−59%. Therefore, deep learning-accelerated MR imaging is a promising and applicable method in musculoskeletal imaging.

Indexed as

Deep LearningMusculoskeletal DiseasesNeoplasmsAdultAgedAged, 80 and overArtifactsExtremitiesHumansMagnetic Resonance ImagingMiddle Agedaccelerated turbo spin echo MRIartificial intelligencedeep learningmusculoskeletal imagingmusculoskeletal tumors

Identifiers

PMID35894013
PMCPMC9326558
OpenAlexW4284898121

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked