Evidence map›Paper›PMID 35910697›Full record

ArticleCureus2022

A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device.

Ramachandra Barik, Rudrapratap Mahapatra

Open access · diamondAbstract readCase Reports
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ramachandra BarikCardiology, All India Institute of Medical Sciences, Bhubaneswar, Bhubaneswar, IND.
Rudrapratap MahapatraCardiothoracic Surgery, All India Institute of Medical Sciences, Bhubaneswar, Bhubaneswar, IND.
All India Institute of Medical Sciences Bhubaneswar · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Device closure of an eccentric atrial septal defect can be challenging and needs technical modifications to avoid unnecessary complications. Here, we present a case of a 45-year-old woman who underwent device closure of an eccentric defect with a large device. The patient developed pericardial effusion and left-sided pleural effusion due to injury to the junction of right atrium and superior vena cava because of the malalignment of the delivery sheath and left atrial disc before the device was pulled across the eccentric defect despite releasing the left atrial disc in the left atrium in place of the left pulmonary vein. These two serious complications were managed conservatively with close monitoring of the case during and after the procedure.

Indexed as

atrial septal defectdevice closureeccentric locationlarge deviceright atrial and superior vena junction injury

Identifiers

PMID35910697
PMCPMC9337235
OpenAlexW4288702522

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.