Evidence map›Paper›PMID 35938231›Full record

ArticlePediatric pulmonology2022

Simultaneous measurement of diaphragm activity, chest impedance, and ECG using three standard cardiorespiratory monitoring electrodes.

Anouk W J Scholten, Ruud W van Leuteren, Frans H de Jongh, Anton H van Kaam, Gerard J Hutten

Open access · hybridAbstract read
In one paragraph

Article in Pediatric pulmonology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Observational
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Anouk W J ScholtenDepartment of Neonatology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0002-6175-1436
Ruud W van LeuterenDepartment of Neonatology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0001-8468-2544
Frans H de JonghDepartment of Neonatology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0002-6052-7504
Anton H van KaamDepartment of Neonatology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0003-4030-7085
Gerard J HuttenDepartment of Neonatology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0003-4368-6519
Amsterdam University Medical Centers · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCurrent cardiorespiratory monitoring in neonates with electrocardiogram (ECG) and chest impedance (CI) has limitations. Adding transcutaneous electromyography of the diaphragm (dEMG) may improve respiratory monitoring, but requires additional hardware. We aimed to determine the feasibility of measuring dEMG and ECG/CI simultaneously using the standard ECG/CI hardware, with its three electrodes repositioned to dEMG electrode locations.

methodsThirty infants (median postmenstrual age 30.4 weeks) were included. First, we assessed the feasibility of extracting dEMG from the ECG-signal. If successful, the agreement between dEMG-based respiratory rate (RR), using three different ECG-leads, and a respiratory reference signal was assessed using the Bland-Altman analysis and the intraclass correlation coefficient (ICC). Furthermore, we studied the agreement between CI-based RR and the reference signal with the electrodes placed at the standard and dEMG position. Finally, we explored the quality of the ECG-signal at the different electrode positions.

resultsIn 15 infants, feasibility of measuring dEMG with the monitoring electrodes was confirmed. In the next 15 infants, comparing dEMG-based RR to the reference signal resulted in a mean difference and limits of agreement for ECG-lead I, II and III of 4.2 [-8.2 to 16.6], 4.3 [-10.7 to 19.3] and 5.0 [-14.2 to 24.2] breaths/min, respectively. ICC analysis showed a moderate agreement for all ECG-leads. CI-based RR agreement was similar at the standard and dEMG electrode position. An exploratory analysis suggested similar quality of the ECG-signal at both electrode positions.

conclusionMeasuring dEMG using the ECG/CI hardware with its electrodes on the diaphragm is feasible, leaving ECG/CI monitoring unaffected.

Indexed as

DiaphragmElectrocardiographyElectric ImpedanceElectrodesHumansInfantInfant, NewbornRespiratory Rateneonatesrespirationtranscutaneous electromyography

Identifiers

PMID35938231
PMCPMC9804169
OpenAlexW4290618074

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.