Evidence map›Paper›PMID 36164574›Full record

ArticleSaudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society2022

Fabric phase sorptive extraction coupled with UPLC-ESI-MS/MS method for fast and sensitive quantitation of tadalafil in a bioequivalence study.

Sameh A Ahmed, Ali M Alalawi, Ahmed M Shehata, Abdulmalik A Alqurshi, Yaser M Alahmadi, Hany S M Ali

Abstract read
In one paragraph

Article in Saudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sameh A AhmedPharmacognosy and Pharmaceutical Chemistry Department, College of Pharmacy Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.
Ali M AlalawiPharmacology and Toxicology Department, College of Pharmacy, Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.
Ahmed M ShehataPharmacology and Toxicology Department, College of Pharmacy, Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.
Abdulmalik A AlqurshiPharmaceutics and Pharmaceutical Technology Department, College of Pharmacy, Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.
Yaser M AlahmadiClinical and Hospital Pharmacy Department, College of Pharmacy, Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.
Hany S M AliPharmaceutics and Pharmaceutical Technology Department, College of Pharmacy, Taibah University, AlMadinah AlMunawarah 30001, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The current study coupled fabric phase sorptive extraction (FPSE) with ultraperformance liquid chromatography method with electrospray ionization and tandem mass detection (UPLC-ESI-MS/MS) for fast and sensitive determination of tadalafil (TAD) in a bioequivalence study. Fabric phase sorptive extraction allowed direct extraction of TAD from the sample matrix with improved selectivity, repeatability, and recoveries. A sol-gel Carbowax 20 M (CX-20 M) coated FPSE membrane revealed the best extraction efficiency for TAD because of its strong affinity for analytes via intermolecular interactions, high mass transfer rate to FPSE membrane, and high permeability. An automated multiple reaction monitoring (MRM) optimizer was employed for the best selection of the precursor and product ions, ion breakdown profile, the fine adjustment of the fragmentor voltages for each precursor ions, and the collision energies for the product ions. The chromatographic separation was conducted using a mobile phase A: 5.0 mM ammonium acetate with 0.1 % formic acid in water and mobile phase B: formic acid (0.1%) in acetonitrile in ratio (55:45, v/v) through isocratic elution mode on an Agilent EclipsePlus C18 (50 × 2.1 mm, 1.8 μm) column and the flow rate was adjusted at 0.4 mL min

Indexed as

Automated MRM OptimizationBioequivalence studyFabric phase sorptive extractionSildenafilTadalafilUPLC-MS/MS

Identifiers

PMID36164574
PMCPMC9508631

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.