Evidence map›Paper›PMID 36233382›Full record

ArticleJournal of clinical medicine2022

Validation of a Novel Patient Specific CT-Morphometric Technique for Quantifying Bone Graft Resorption Following the Latarjet Procedure.

Fraser W Francis-Pester, Manuel Waltenspül, Karl Wieser, Greg Hoy, Eugene T Ek, David C Ackland, Lukas Ernstbrunner

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 2 countries.

Fraser W Francis-PesterANU Medical School, Australian National University (ANU), Canberra, ACT 2601, Australia.ORCID 0000-0001-5892-0350
Manuel WaltenspülDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland.
Karl WieserDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland.
Greg HoyMelbourne Orthopaedic Group, Windsor, VIC 3181, Australia.
Eugene T EkMelbourne Orthopaedic Group, Windsor, VIC 3181, Australia.
David C AcklandDepartment of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia.
Lukas ErnstbrunnerMelbourne Orthopaedic Group, Windsor, VIC 3181, Australia.ORCID 0000-0003-4920-8518
Hollywood Orthopaedic Group · AUUniversity of Zurich · CHAustralian National University · AUThe Royal Melbourne Hospital · AUThe University of Melbourne · AU

Funding

AGA-Gesellschaft für Arthroskopie und Gelenkchirurgie 78
6 · The paper itself

Abstract

Bone graft resorption following the Latarjet procedure has received considerable concern. Current methods quantifying bone graft resorption rely on two-dimensional (2D) CT-scans or three-dimensional (3D) techniques, which do not represent the whole graft volume/resorption (i.e., 2D assessment) or expose patients to additional radiation (i.e., 3D assessment) as this technique relies on early postoperative CT-scans. The aim of the present study was to develop and validate a patient-specific, CT-morphometric technique combining image registration with 3D CT-reconstruction to quantify bone graft resorption following the Latarjet procedure for recurrent anterior shoulder instability. Pre-operative and final follow-up CT-scans were segmented to digitally reconstruct 3D scapula geometries. A virtual Latarjet procedure was then conducted to model the timepoint-0 graft volume, which was compared with the final follow-up graft volume. Graft resorption at final follow-up was highly correlated to the 2D gold standard-technique by Zhu (Kendall tau coefficient = 0.73; p < 0.001). The new technique was also found to have excellent inter- and intra-rater reliability (ICC values, 0.931 and 0.991; both p < 0.001). The main finding of this study is that the technique presented is a valid and reliable method that provides the advantage of 3D-assessment of graft resorption at long-term follow-up without the need of an early postoperative CT-scan.

Indexed as

3D assessmentanterior instabilitycomputed tomography (CT)graft resorptionLatarjetmorphometric analysis

Identifiers

PMID36233382
PMCPMC9571787
OpenAlexW4296481815

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.