Evidence map›Paper›PMID 36325111›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2021

Triple-modality co-registered endoscope featuring wide-field reflectance imaging, and high-resolution multiphoton and optical coherence microscopy.

David Vega, Dominique Galvez, Gabriella Romano, Nancy Y Pham, Ricky Cordova, Makenna Aitken, Sartanee Suebka, John Heusinkveld, Jennifer K Barton

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

David VegaThe University of Arizona, The James C Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, USA, 85721.
Dominique GalvezThe University of Arizona, The James C Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, USA, 85721.
Gabriella RomanoUniversity of Arizona, Biomedical Engineering, The University of Arizona, Tucson, AZ, USA, 85721.
Nancy Y PhamUniversity of Arizona, Biomedical Engineering, The University of Arizona, Tucson, AZ, USA, 85721.
Ricky CordovaUniversity of Arizona, Biomedical Engineering, The University of Arizona, Tucson, AZ, USA, 85721.
Makenna AitkenUniversity of Arizona, Biomedical Engineering, The University of Arizona, Tucson, AZ, USA, 85721.
Sartanee SuebkaThe University of Arizona, The James C Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, USA, 85721.
John HeusinkveldUniversity of Arizona, Department of Obstetrics and Gynecology, College of Medicine, The University of Arizona, Tucson, AZ, USA, 85721.
Jennifer K BartonThe University of Arizona, The James C Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, USA, 85721.

Funding

Advanced Salpingoscope for Minimally-Invasive Imaging of the Fallopian TubesR01EB020605 · NIBIB · UNIVERSITY OF ARIZONA · PI BARTON, JENNIFER KEHLET · 2016 to 2019
$1.3M
NIBIB NIH HHS R01 EB020605
6 · The paper itself

Abstract

We present the design and feasibility testing of a multimodal co-registered endoscope based on a dual-path optical system integrated with a scanning piezo. This endoscope incorporates three different imaging modalities. A large field of view reflectance imaging system enables visualization of objects several millimeters in front of the endoscope, while optical coherence microscopy and multiphoton microscopy are employed in contact with tissue to further analyze suspicious areas. The optical system allows multiple different imaging modalities by employing a dual optical path. One path features a low numerical aperture and wide field of view to allow reflectance imaging of distant objects. The other path features a high numerical aperture and short working distance to allow microscopy techniques such as optical coherence microscopy and multiphoton microscopy. Images of test targets were obtained with each imaging modality to verify and characterize the imaging capabilities of the endoscope. The reflectance modality was demonstrated with a 561 nm laser to allow high contrast with blood vessels. It achieved a lateral resolution of 24.8 μm at 5 mm and a working distance from 5 mm to 30 mm. Optical coherence microscopy (OCM) was performed with a 1300 nm super-luminescent diode since this wavelength experiences low relative scattering to allow for deeper tissue imaging. Measured OCM lateral and axial resolution was 4.0 μm and 14.2 μm, respectively. Multiphoton microscopy (MPM) was performed with a custom 1400 nm femtosecond fiber laser, a wavelength suitable for exciting multiple exogenous and some endogenous fluorophores, as well as providing information on tissue composition through harmonic generation processes. A 4.0 μm MPM lateral resolution was measured.

Indexed as

co-registered imagingmultimodal endoscopesmultiphoton endoscopeOptical coherence tomography endoscope

Identifiers

PMID36325111
PMCPMC9625855

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.