Evidence map›Paper›PMID 36377191›Full record

ArticleExperimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association2023

Accuracy of Flash Glucose Monitoring in Hemodialysis Patients With and Without Diabetes Mellitus.

Michèle R Weber, Matthias Diebold, Peter Wiesli, Andreas D Kistler

Open access · hybridAbstract read
In one paragraph

Article in Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Michèle R WeberDepartment of Medicine, Cantonal Hospital Frauenfeld, Frauenfeld, Switzerland.
Matthias DieboldClinic for Transplantation Immunology and Nephrology, University Hospital Basel, University of Basel, Basel, Switzerland.
Peter WiesliDepartment of Medicine, Cantonal Hospital Frauenfeld, Frauenfeld, Switzerland.
Andreas D KistlerDepartment of Medicine, Cantonal Hospital Frauenfeld, Frauenfeld, Switzerland.
Kantonsspital Frauenfeld · CHUniversity of Basel · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsGlucose and insulin metabolism are altered in hemodialysis patients, and diabetes management is difficult in these patients. We aimed to validate flash glucose monitoring (FGM) in hemodialysis patients with and without diabetes mellitus as an attractive option for glucose monitoring not requiring regular self-punctures.

methodsWe measured interstitial glucose using a FreeStyle Libre device in eight hemodialysis patients with and seven without diabetes mellitus over 14 days and compared the results to simultaneously performed self-monitoring of capillary blood glucose (SMBG).

resultsIn 720 paired measurements, mean flash glucose values were significantly lower than self-measured capillary values (6.17±2.52 vs. 7.15±2.41 mmol/L, p=1.3 E-86). Overall, the mean absolute relative difference was 17.4%, and the mean absolute difference was 1.20 mmol/L. The systematic error was significantly larger in patients without vs. with diabetes (- 1.17 vs. - 0.82 mmol/L) and on dialysis vs. interdialytic days (-1.09 vs. -0.90 mmol/L). Compared to venous blood glucose (72 paired measurements), the systematic error of FGM was even larger (5.89±2.44 mmol/L vs. 7.78±7.25 mmol/L, p=3.74E-22). Several strategies to reduce the systematic error were evaluated, including the addition of +1.0 mmol/L as a correction term to all FGM values, which significantly improved accuracy.

conclusionsFGM systematically underestimates blood glucose in hemodialysis patients but, taking this systematic error into account, the system may be useful for glucose monitoring in hemodialysis patients with or without diabetes.

Indexed as

Diabetes Mellitus, Type 1Diabetes Mellitus, Type 2Blood GlucoseBlood Glucose Self-MonitoringHumansBlood Glucose

Identifiers

PMID36377191
PMCPMC9998185
OpenAlexW4309095913

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.